Use of a liquid chromatography-tandem mass spectrometry method to assess the concentration of epinephrine, norepinephrine, and phenylephrine stored in plastic syringes

There are concerns about the potency of epinephrine (EPI), norepinephrine (NE), and phenylephrine (PE) stored in syringes for later infusions in clinical care. The objective of our study was to optimize a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to determine the concentration...

Full description

Saved in:
Bibliographic Details
Main Authors: Cohen Alejandro M. (Author), Wiseman Luke (Author), Al Faraj Ahmed (Author), Andreou Pantelis (Author), Hall Richard (Author), Neira Victor M. (Author)
Format: Book
Published: De Gruyter, 2023-04-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:There are concerns about the potency of epinephrine (EPI), norepinephrine (NE), and phenylephrine (PE) stored in syringes for later infusions in clinical care. The objective of our study was to optimize a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to determine the concentrations EPI, NE, and PE dissolved in normal saline and stored in 50 mL 3-part Becton Dickinson syringes.
Item Description:2365-2411
2365-242X
10.1515/pthp-2022-0010