Development and validation of determination of genotoxic impurity Bromoethane in Vigabatrin drug substance using head space gas chromatographic method [HS-GC]
A specific HS-GC method has been developed, optimized, and validated for the determination of genotoxic impurity Bromoethane in Vigabatrin (VGB) drug substance. Chromatographic separation of genotoxic Bromoethane impurity was achieved on DB-1 column (30 m × 0.53 mm, 5.0 μm), consists of 100% dimethy...
Saved in:
Main Authors: | , |
---|---|
Format: | Book |
Published: |
Pensoft Publishers,
2023-03-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_43d96d83a9a64a6facb25b88e676ec18 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Krishan Prasad Narapereddy |e author |
700 | 1 | 0 | |a Devi Sravanthi Alladi |e author |
245 | 0 | 0 | |a Development and validation of determination of genotoxic impurity Bromoethane in Vigabatrin drug substance using head space gas chromatographic method [HS-GC] |
260 | |b Pensoft Publishers, |c 2023-03-01T00:00:00Z. | ||
500 | |a 10.3897/pharmacia.70.e97339 | ||
500 | |a 2603-557X | ||
520 | |a A specific HS-GC method has been developed, optimized, and validated for the determination of genotoxic impurity Bromoethane in Vigabatrin (VGB) drug substance. Chromatographic separation of genotoxic Bromoethane impurity was achieved on DB-1 column (30 m × 0.53 mm, 5.0 μm), consists of 100% dimethyl polysiloxane as stationary phase and passing nitrogen carrier gas. The performance of the method was assessed by evaluating the specificity, linearity, sensitivity, precision, and accuracy experiments. The established limit of detection and limit of quantification values for the genotoxic impurity was in the range of 3.57-10.80 μg/mL. The correlation coefficient value of the linearity experiment was 0.9880. The average recoveries for the accuracy were in the range of 95.3-106.8%. The results proved that the method is suitable for the determination of Bromoethane content in Vigabatrin. | ||
546 | |a EN | ||
690 | |a Pharmacy and materia medica | ||
690 | |a RS1-441 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n Pharmacia, Vol 70, Iss 1, Pp 203-207 (2023) | |
787 | 0 | |n https://pharmacia.pensoft.net/article/97339/download/pdf/ | |
787 | 0 | |n https://pharmacia.pensoft.net/article/97339/download/xml/ | |
787 | 0 | |n https://pharmacia.pensoft.net/article/97339/ | |
787 | 0 | |n https://doaj.org/toc/2603-557X | |
856 | 4 | 1 | |u https://doaj.org/article/43d96d83a9a64a6facb25b88e676ec18 |z Connect to this object online. |