Dentin penetrability evaluation of three different dyes in root-end cavities filled with mineral trioxide aggregate (MTA) Avaliação da penetração dentinária de três diferentes corantes em retrocavidades obturadas com agregado trióxido mineral (MTA)

The purpose of this study was to evaluate the penetration of three dyes in MTA root-end fillings. In 30 single-rooted teeth, cavities for retrofilling were prepared with an ultrasound appliance and filled with MTA. The specimens were randomly assigned to three groups (n = 10) and immersed in the fol...

Full description

Saved in:
Bibliographic Details
Main Authors: Beatriz Farias Vogt (Author), Cristina Braga Xavier (Author), Flávio Fernando Demarco (Author), Marcio Schüler Padilha (Author)
Format: Book
Published: Sociedade Brasileira de Pesquisa Odontológica, 2006-04-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The purpose of this study was to evaluate the penetration of three dyes in MTA root-end fillings. In 30 single-rooted teeth, cavities for retrofilling were prepared with an ultrasound appliance and filled with MTA. The specimens were randomly assigned to three groups (n = 10) and immersed in the following solutions: 2% methylene blue (MET), 50% silver nitrate (NIT) and 0.2% rhodamine B (ROD). Two transversal slices (1 mm) of the retrofilling region were obtained and evaluated using the Image Tool 3.0 software to obtain a quantitative evaluation (in mm²) of the dye penetration around the retrofillings. Data were submitted to statistical analysis using Student's t-test. The lowest degree of dye penetration was observed for the NIT group, in both slices (p < 0.05). Dye penetration was significantly larger in the ROD group when compared to the NIT group, in both slices (p < 0.05), and to the MET group, only in slice 1 (p < 0.05). Within the limitations of this study, it was concluded that the choice of dye could influence the penetration evaluation in root-end filling studies, and that the NIT had the lowest penetration capacity in the apical dentine.<br>A proposta deste trabalho foi avaliar a penetração de três corantes em retrocavidades obturadas com MTA. As retrocavidades foram confeccionadas com aparelho de ultra-som em 30 dentes unirradiculares e obturadas com MTA. Os espécimes foram divididos aleatoriamente em três grupos (n = 10) e imersos nas seguintes soluções corantes: azul de metileno a 2% (MET), nitrato de prata a 50% (NIT) e rodamina B a 0,2% (ROD). Duas fatias transversais (1 mm) da região retrobturada foram obtidas e avaliadas através do software Image Tool 3.0, objetivando quantificar a área (em mm²) de penetração do corante ao redor das retrobturações. Os dados foram submetidos à análise estatística, utilizando o teste t de Student. A menor área de penetração foi observada no grupo NIT, nas duas fatias (p < 0.05). A penetração de corante foi significativamente maior no grupo ROD quando comparado ao grupo NIT, nas duas fatias (p < 0.05), e ao grupo MET, somente na fatia 1 (p < 0.05). Dentro das limitações desta pesquisa, concluiu-se que a escolha da solução corante pode influenciar a avaliação da penetração em estudos sobre retrobturações e que o grupo NIT teve a menor capacidade de penetração na dentina apical.
Item Description:10.1590/S1806-83242006000200008
1806-8324