The Effect of Symmetric and Asymmetric Loading of Frontal Segment with Two Curved Cantilevers: An In Vitro Study

Cantilevers generate statically determined force systems. The frontal segment loading with symmetric and asymmetric cantilevers in a three-piece intrusion base arch can be used to correct midline asymmetry. Three types of 0.017" × 0.025" beta-titanium cantilevers: tip-back (TB), deep curve...

Cur síos iomlán

Sábháilte in:
Sonraí bibleagrafaíochta
Príomhchruthaitheoirí: Malgorzata Bilinska (Údar), Michel Dalstra (Údar)
Formáid: LEABHAR
Foilsithe / Cruthaithe: MDPI AG, 2022-03-01T00:00:00Z.
Ábhair:
Rochtain ar líne:Connect to this object online.
Clibeanna: Cuir clib leis
Níl clibeanna ann, Bí ar an gcéad duine le clib a chur leis an taifead seo!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_4669d20a0a3f45daa2d63d1dddf4d730
042 |a dc 
100 1 0 |a Malgorzata Bilinska  |e author 
700 1 0 |a Michel Dalstra  |e author 
245 0 0 |a The Effect of Symmetric and Asymmetric Loading of Frontal Segment with Two Curved Cantilevers: An In Vitro Study 
260 |b MDPI AG,   |c 2022-03-01T00:00:00Z. 
500 |a 10.3390/dj10040052 
500 |a 2304-6767 
520 |a Cantilevers generate statically determined force systems. The frontal segment loading with symmetric and asymmetric cantilevers in a three-piece intrusion base arch can be used to correct midline asymmetry. Three types of 0.017" × 0.025" beta-titanium cantilevers: tip-back (TB), deep curve (DC), utility arch (UA) were tested on typodonts simulating intrusion of the maxillary anterior segment. Typodonts with symmetric and asymmetric cantilevers were scanned with intraoral scanner (3Shape, TRIOS, Copenhagen, Denmark) before (T0) and after (T1) the experiment, scans were superimposed using Mimics software (Materialise, Leuven, Belgium). Data were analysed with qualitative analysis. All cantilevers generated vertical and horizontal forces. For symmetric design, the DC and TB displayed intrusive force with retrusive component, UA intrusion and protrusion. The asymmetric cantilevers produced transverse displacement of anterior segment. DC created lateral, UA medial force, the anterior segment displacement was consistent with the used configuration. The movement of an anterior segment with TB is smaller compared to DC and UA. Symmetric cantilevers configurations can achieve simultaneous intrusion and retrusion or protrusion of the anterior segment. The asymmetric design with transversal force can clinically aid the correction of midline discrepancies. The effect of the cantilever configuration on delivered force direction was confirmed. 
546 |a EN 
690 |a cantilevers 
690 |a dental asymmetry 
690 |a midline correction 
690 |a three-piece intrusion arch 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Dentistry Journal, Vol 10, Iss 4, p 52 (2022) 
787 0 |n https://www.mdpi.com/2304-6767/10/4/52 
787 0 |n https://doaj.org/toc/2304-6767 
856 4 1 |u https://doaj.org/article/4669d20a0a3f45daa2d63d1dddf4d730  |z Connect to this object online.