Analysis of sliding mechanics force degradation during postextraction space closure

Introduction Due to its simplicity, sliding mechanism is very often used in clinical practice for post-extraction space closure, however, the efficiency of this method may be reduced due to friction and changes in the properties of the materials used in this method. The most commonly used methods of...

Full description

Saved in:
Bibliographic Details
Main Authors: Umićević-Davidović Mirjana (Author), Arapović-Savić Marijana (Author), Arbutina Adriana (Author), Adamović Tijana (Author), Kuzmanović-Radman Irena (Author)
Format: Book
Published: Serbian Medical Society - Dental Section, Belgrade, 2022-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_476e4f5bd9be4bc9a12fe6d2689f9d9b
042 |a dc 
100 1 0 |a Umićević-Davidović Mirjana  |e author 
700 1 0 |a Arapović-Savić Marijana  |e author 
700 1 0 |a Arbutina Adriana  |e author 
700 1 0 |a Adamović Tijana  |e author 
700 1 0 |a Kuzmanović-Radman Irena  |e author 
245 0 0 |a Analysis of sliding mechanics force degradation during postextraction space closure 
260 |b Serbian Medical Society - Dental Section, Belgrade,   |c 2022-01-01T00:00:00Z. 
500 |a 0039-1743 
500 |a 1452-3701 
500 |a 10.2298/SGS2203115U 
520 |a Introduction Due to its simplicity, sliding mechanism is very often used in clinical practice for post-extraction space closure, however, the efficiency of this method may be reduced due to friction and changes in the properties of the materials used in this method. The most commonly used methods of sliding mechanics are nickel titanium (NiTi) closed coil spring and elastic chain. The aim of this study was to analyze force degradation in the application of nickel titanium closed coil springs and elastic chains during post-extraction space closure within treatment with fixed orthodontic appliances. Material and Methods The total sample in this study consisted of 78 post-extraction spaces in patients who were indicated for extraction of first premolars and treatment with fixed orthodontic appliances. Nickel titanium closed coil springs and elastic chains were used to close the post-extraction spaces. Post-extraction spaces were monitored for 6 months with follow up examinations every 4 weeks. Measurements of initial force, at the beginning of mechanism activation and residual force in the observation period were performed during control examinations. Results Results of this research showed that with both methods of sliding mechanism there was a significant decrease in the observation period. When using NiTi closed coil springs, the value of average initial force at control examination was between 189.00-210.25 g, while residual was in the range of 117.56-133.50 g that NiTi closed coil springs kept an average 61.57% of initial force. The average initial force on the control examinations for elastic chains was between 184.5-205.38 g, while residual force was in range of 100.39-113.00 g, that elastic chains retained an average 53.41% of initial force. Conclusion There was a significant force degradation between inspections, when sliding mechanics were applied. The loss of force between activation phases of NiTi closed coil springs was smaller compared to the forces produced by elastic chains. 
546 |a EN 
546 |a SR 
690 |a sliding mechanics 
690 |a elastic chain 
690 |a niti closed coil spring 
690 |a post-extraction space 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Stomatološki glasnik Srbije, Vol 69, Iss 3, Pp 115-124 (2022) 
787 0 |n https://scindeks-clanci.ceon.rs/data/pdf/0039-1743/2022/0039-17432203115U.pdf 
787 0 |n https://doaj.org/toc/0039-1743 
787 0 |n https://doaj.org/toc/1452-3701 
856 4 1 |u https://doaj.org/article/476e4f5bd9be4bc9a12fe6d2689f9d9b  |z Connect to this object online.