Light Conduction Capability of Different Light-Transmitting

Introduction: Application of light transmitting posts to restore greatly damaged endodontically treated teeth has been increased. It is suspected that light intensity decreases as it passes throughout different materials. This can reduce the degree of conversion required for adequate bond strength t...

Full description

Saved in:
Bibliographic Details
Main Authors: Saied Mostafa Moazzami (Author), Reza Kazemi (Author), Maliheh Alami (Author), Ebrahim Attaran (Author), Michael Mehhary (Author), Majid Sarmad (Author), Heydar Shahrokh (Author)
Format: Book
Published: Mashhad University of Medical Sciences, 2012-09-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_49797585e6bd40c7b15d2a00d01d3bb0
042 |a dc 
100 1 0 |a Saied Mostafa Moazzami  |e author 
700 1 0 |a Reza Kazemi  |e author 
700 1 0 |a Maliheh Alami  |e author 
700 1 0 |a Ebrahim Attaran  |e author 
700 1 0 |a Michael Mehhary  |e author 
700 1 0 |a Majid Sarmad  |e author 
700 1 0 |a Heydar Shahrokh  |e author 
245 0 0 |a Light Conduction Capability of Different Light-Transmitting 
260 |b Mashhad University of Medical Sciences,   |c 2012-09-01T00:00:00Z. 
500 |a 2322-4150 
500 |a 2252-0317 
520 |a Introduction: Application of light transmitting posts to restore greatly damaged endodontically treated teeth has been increased. It is suspected that light intensity decreases as it passes throughout different materials. This can reduce the degree of conversion required for adequate bond strength throughout the length of these posts. The objective of this study was to evaluate the amount of light intensity reduction after passing through different depths of FRC posts. Methods: Four groups of five extracted human central incisors were prepared to cement four types of FRC posts with Panavia F 2 resin cement. The apical end of the posts were exposed by sectioning with a diamond disk and then polished. The light intensity measurement was performed using a micro-voltmeter in 8 points or depths with 2mm intervals beginning from the apical depth of 16mm up to a coronal depth of 6mm. Two different output light intensities [HIP (High Intensity Program) and LOP (Low Intensity Program)] were evaluated. Results: Statistical analysis showed significant differences in light intensity at various depths between 6 and 16mm in all groups. These reductions were linear in all specimens; however, the rate of reduction was dissimilar among different FRC posts. HIP and LOP light exposure modes had not the same rate of light reduction. Conclusion: Light intensity decreased dramatically after passing through different depths of FRC posts. None of the posts had sufficient enough light transmission for satisfactory polymerization at the apical and middle levels. 
546 |a EN 
690 |a FRC post 
690 |a light intensity 
690 |a light transmitting post 
690 |a thickness 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Journal of Dental Materials and Techniques, Vol 1, Iss 2, Pp 40-46 (2012) 
787 0 |n http://jdmt.mums.ac.ir/?_action=showPDF&article=92&_ob=091205d8e4943796cff48fdb1fc819ab&fileName=full_text.pdf 
787 0 |n https://doaj.org/toc/2322-4150 
787 0 |n https://doaj.org/toc/2252-0317 
856 4 1 |u https://doaj.org/article/49797585e6bd40c7b15d2a00d01d3bb0  |z Connect to this object online.