In vitro cytotoxicity of four calcium silicate-based endodontic cements on human monocytes, a colorimetric MTT assay

Objectives This study was performed to evaluate the cytotoxicity of four calcium silicate-based endodontic cements at different storage times after mixing. Materials and Methods Capillary tubes were filled with Biodentine (Septodont), Calcium Enriched Mixture (CEM cement, BioniqueDent), Tech Bioseal...

Full description

Saved in:
Bibliographic Details
Main Authors: Sedigheh Khedmat (Author), Somayyeh Dehghan (Author), Jamshid Hadjati (Author), Farimah Masoumi (Author), Mohammad Hossein Nekoofar (Author), Paul Michael Howell Dummer (Author)
Format: Book
Published: Korean Academy of Conservative Dentistry, 2014-08-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_4b87823f6a324cf29eabeb211e6e15f5
042 |a dc 
100 1 0 |a Sedigheh Khedmat  |e author 
700 1 0 |a Somayyeh Dehghan  |e author 
700 1 0 |a Jamshid Hadjati  |e author 
700 1 0 |a Farimah Masoumi  |e author 
700 1 0 |a Mohammad Hossein Nekoofar  |e author 
700 1 0 |a Paul Michael Howell Dummer  |e author 
245 0 0 |a In vitro cytotoxicity of four calcium silicate-based endodontic cements on human monocytes, a colorimetric MTT assay 
260 |b Korean Academy of Conservative Dentistry,   |c 2014-08-01T00:00:00Z. 
500 |a 10.5395/rde.2014.39.3.149 
500 |a 2234-7658 
500 |a 2234-7666 
520 |a Objectives This study was performed to evaluate the cytotoxicity of four calcium silicate-based endodontic cements at different storage times after mixing. Materials and Methods Capillary tubes were filled with Biodentine (Septodont), Calcium Enriched Mixture (CEM cement, BioniqueDent), Tech Biosealer Endo (Tech Biosealer) and ProRoot MTA (Dentsply Tulsa Dental). Empty tubes and tubes containing Dycal were used as negative and positive control groups respectively. Filled capillary tubes were kept in 0.2 mL microtubes and incubated at 37℃. Each material was divided into 3 groups for testing at intervals of 24 hr, 7 day and 28 day after mixing. Human monocytes were isolated from peripheral blood mononuclear cells and cocultered with 24 hr, 7 day and 28 day samples of different materials for 24 and 48 hr. Cell viability was evaluated using an MTT assay. Results In all groups, the viability of monocytes significantly improved with increasing storage time regardless of the incubation time (p < 0.001). After 24 hr of incubation, there was no significant difference between the materials regarding monocyte viability. However, at 48 hr of incubation, ProRoot MTA and Biodentine were less cytotoxic than CEM cement and Biosealer (p < 0.01). Conclusions Biodentine and ProRoot MTA had similar biocompatibility. Mixing ProRoot MTA with PBS in place of distilled water had no effect on its biocompatibility. Biosealer and CEM cement after 48 hr of incubation were significantly more cytotoxic to on monocyte cells compared to ProRoot MTA and Biodentine. 
546 |a EN 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Restorative Dentistry & Endodontics, Vol 39, Iss 3, Pp 149-154 (2014) 
787 0 |n https://doi.org/10.5395/rde.2014.39.3.149 
787 0 |n https://doaj.org/toc/2234-7658 
787 0 |n https://doaj.org/toc/2234-7666 
856 4 1 |u https://doaj.org/article/4b87823f6a324cf29eabeb211e6e15f5  |z Connect to this object online.