AN LC- MS/MS METHOD FOR THE DETERMINATION OF OMEPRAZOLE ON PROTON PUMP INHIBITOR IN HUMAN PLASMA

A sensitive and selective liquid chromatographic method coupled with tandem mass spectroscopy (LC-MS/MS) was developed for the quantification of omeprazole in human plasma. Lansoprazole was used as internal standard with plasma samples, extracted using 10mM ammonium acetate. A centrifuged upper laye...

Disgrifiad llawn

Wedi'i Gadw mewn:
Manylion Llyfryddiaeth
Prif Awduron: T. Sudha (Awdur), Kalan Kumar Reddy (Awdur), P. V. Hemalatha (Awdur), V. R. Ravikumar (Awdur)
Fformat: Llyfr
Cyhoeddwyd: Universitas Gadjah Mada, 2016-04-01T00:00:00Z.
Pynciau:
Mynediad Ar-lein:Connect to this object online.
Tagiau: Ychwanegu Tag
Dim Tagiau, Byddwch y cyntaf i dagio'r cofnod hwn!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_4d75bb498b1f45dfafe24f8e014f5a4f
042 |a dc 
100 1 0 |a T. Sudha   |e author 
700 1 0 |a Kalan Kumar Reddy  |e author 
700 1 0 |a P. V. Hemalatha  |e author 
700 1 0 |a V. R. Ravikumar  |e author 
245 0 0 |a AN LC- MS/MS METHOD FOR THE DETERMINATION OF OMEPRAZOLE ON PROTON PUMP INHIBITOR IN HUMAN PLASMA 
260 |b Universitas Gadjah Mada,   |c 2016-04-01T00:00:00Z. 
500 |a 10.14499/indonesianjpharm27iss2pp80 
500 |a 2338-9427 
500 |a 2338-9486 
520 |a A sensitive and selective liquid chromatographic method coupled with tandem mass spectroscopy (LC-MS/MS) was developed for the quantification of omeprazole in human plasma. Lansoprazole was used as internal standard with plasma samples, extracted using 10mM ammonium acetate. A centrifuged upper layer was then evaporated and reconstituted with Acetonitrile: mobile phase buffer 70:30%v/v. The reconstructed samples were injected into a C18 column purospher star 5µ. The mobile phase was composed of ACN: mobile phase buffer (5mm ammonium bicarbonate buffer) in the ratio of 70:30%v/v with flow rate 1.0mL/min. The mass spectrometer was operated using positive ion mode and turbo electro spray ionisation. Nitrogen was used as the nebulizer, curtain, collision and auxiliary gases. Using MS/MS with multiple reactions monitoring (MRM) mode, omeprazole was detected without severe interferences from plasma matrix. Detection of omeprazole in human plasma was accurate and precision. This method has been successfully applied to the study of omeprazole in human specimens 
546 |a EN 
690 |a Proton pump inhibitor 
690 |a omeprazole 
690 |a lansoprazole 
690 |a LC-MS/MS 
690 |a liquid liquid extraction 
690 |a Pharmacy and materia medica 
690 |a RS1-441 
655 7 |a article  |2 local 
786 0 |n Indonesian Journal of Pharmacy, Vol 27, Iss 2, Pp 80-91 (2016) 
787 0 |n http://indonesianjpharm.farmasi.ugm.ac.id/index.php/3/article/view/1062 
787 0 |n https://doaj.org/toc/2338-9427 
787 0 |n https://doaj.org/toc/2338-9486 
856 4 1 |u https://doaj.org/article/4d75bb498b1f45dfafe24f8e014f5a4f  |z Connect to this object online.