Evaluation of the adaptation interface of one-piece implant-supported superstructures obtained in Ni-Cr-Ti and Pd-Ag alloys
Several formulations of alternative alloys have been proposed for the substitution of gold-based alloys used in Dentistry. Recently, a Ni-Cr-Ti-based alloy has been introduced. The purpose of this work was to verify the marginal adaptation obtained with one-piece superstructures for implant-supporte...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Book |
Published: |
Fundação Odontológica de Ribeirão Preto,
2003-01-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_4dd93c103fd0412489467aff6b739ab2 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Costa Heloisa Módena Ferreira da |e author |
700 | 1 | 0 | |a Rodrigues Renata Cristina Silveira |e author |
700 | 1 | 0 | |a Mattos Maria da Glória Chiarello de |e author |
700 | 1 | 0 | |a Ribeiro Ricardo Faria |e author |
245 | 0 | 0 | |a Evaluation of the adaptation interface of one-piece implant-supported superstructures obtained in Ni-Cr-Ti and Pd-Ag alloys |
260 | |b Fundação Odontológica de Ribeirão Preto, |c 2003-01-01T00:00:00Z. | ||
500 | |a 0103-6440 | ||
520 | |a Several formulations of alternative alloys have been proposed for the substitution of gold-based alloys used in Dentistry. Recently, a Ni-Cr-Ti-based alloy has been introduced. The purpose of this work was to verify the marginal adaptation obtained with one-piece superstructures for implant-supported prostheses obtained in Ni-Cr-Ti alloy, compared to a semi-noble alloy Pd-Ag. Eight superstructures for each alloy were produced over 4 implants in the anterior region of the mandible. The superstructures were placed in a torquemeter and the fixation screw of implant #1 was tightened with a 20 Ncm load with the others loosened (Sheffield test). The unfitness (in mm) was measured using a three-dimensional optical measurer in each implant, in the buccal and lingual aspects. The obtained data were submitted to statistical analysis by the analysis of variance and Tukey's test at 5% level. Significant differences were found for the factors material (p<0.05), with Ni-Cr-Ti pieces better than Pd-Ag ones, and implants (p<0.01). There were no significant differences for the factor position and interactions among factors (p>0.05). Based on the analysis of the data, it is possible to conclude that the Ni-Cr-Ti alloy makes possible the obtainment of one-piece implant-supported superstructures with a smaller misfit compared to the one obtained in Pd-Ag alloy, traditionally indicated for this situation. Additional tests may verify the superiority of the Ni-Cr-Ti alloy. | ||
546 | |a EN | ||
690 | |a chromium alloys | ||
690 | |a titanium | ||
690 | |a implants | ||
690 | |a Dentistry | ||
690 | |a RK1-715 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n Brazilian Dental Journal, Vol 14, Iss 3, Pp 197-202 (2003) | |
787 | 0 | |n http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402003000300011 | |
787 | 0 | |n https://doaj.org/toc/0103-6440 | |
856 | 4 | 1 | |u https://doaj.org/article/4dd93c103fd0412489467aff6b739ab2 |z Connect to this object online. |