Evaluation of the adaptation interface of one-piece implant-supported superstructures obtained in Ni-Cr-Ti and Pd-Ag alloys

Several formulations of alternative alloys have been proposed for the substitution of gold-based alloys used in Dentistry. Recently, a Ni-Cr-Ti-based alloy has been introduced. The purpose of this work was to verify the marginal adaptation obtained with one-piece superstructures for implant-supporte...

Full description

Saved in:
Bibliographic Details
Main Authors: Costa Heloisa Módena Ferreira da (Author), Rodrigues Renata Cristina Silveira (Author), Mattos Maria da Glória Chiarello de (Author), Ribeiro Ricardo Faria (Author)
Format: Book
Published: Fundação Odontológica de Ribeirão Preto, 2003-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_4dd93c103fd0412489467aff6b739ab2
042 |a dc 
100 1 0 |a Costa Heloisa Módena Ferreira da  |e author 
700 1 0 |a Rodrigues Renata Cristina Silveira  |e author 
700 1 0 |a Mattos Maria da Glória Chiarello de  |e author 
700 1 0 |a Ribeiro Ricardo Faria  |e author 
245 0 0 |a Evaluation of the adaptation interface of one-piece implant-supported superstructures obtained in Ni-Cr-Ti and Pd-Ag alloys 
260 |b Fundação Odontológica de Ribeirão Preto,   |c 2003-01-01T00:00:00Z. 
500 |a 0103-6440 
520 |a Several formulations of alternative alloys have been proposed for the substitution of gold-based alloys used in Dentistry. Recently, a Ni-Cr-Ti-based alloy has been introduced. The purpose of this work was to verify the marginal adaptation obtained with one-piece superstructures for implant-supported prostheses obtained in Ni-Cr-Ti alloy, compared to a semi-noble alloy Pd-Ag. Eight superstructures for each alloy were produced over 4 implants in the anterior region of the mandible. The superstructures were placed in a torquemeter and the fixation screw of implant #1 was tightened with a 20 Ncm load with the others loosened (Sheffield test). The unfitness (in mm) was measured using a three-dimensional optical measurer in each implant, in the buccal and lingual aspects. The obtained data were submitted to statistical analysis by the analysis of variance and Tukey's test at 5% level. Significant differences were found for the factors material (p<0.05), with Ni-Cr-Ti pieces better than Pd-Ag ones, and implants (p<0.01). There were no significant differences for the factor position and interactions among factors (p>0.05). Based on the analysis of the data, it is possible to conclude that the Ni-Cr-Ti alloy makes possible the obtainment of one-piece implant-supported superstructures with a smaller misfit compared to the one obtained in Pd-Ag alloy, traditionally indicated for this situation. Additional tests may verify the superiority of the Ni-Cr-Ti alloy. 
546 |a EN 
690 |a chromium alloys 
690 |a titanium 
690 |a implants 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Brazilian Dental Journal, Vol 14, Iss 3, Pp 197-202 (2003) 
787 0 |n http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402003000300011 
787 0 |n https://doaj.org/toc/0103-6440 
856 4 1 |u https://doaj.org/article/4dd93c103fd0412489467aff6b739ab2  |z Connect to this object online.