Evaluation of torque loss value of MAD/MAM zirconia abutments with prefabricated titanium abutments

Background and Aims: In response to esthetic demand of patients, ceramic abutments have been developed. Despite esthetic of zirconia abutments, machining accuracy of these abutments has always been a question. Any misfit in the abutment-implant interface connection can lead to detorque and screw loo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Marzieh Alikhasi (VerfasserIn), Roshanak Baghaie (VerfasserIn), Nasim khosronejad (VerfasserIn)
Format: Buch
Veröffentlicht: Tehran University of Medical Sciences, 2013-04-01T00:00:00Z.
Schlagworte:
Online-Zugang:Connect to this object online.
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_4edabc608ceb47cda2b56f04f9fa93b6
042 |a dc 
100 1 0 |a Marzieh Alikhasi  |e author 
700 1 0 |a Roshanak Baghaie  |e author 
700 1 0 |a Nasim khosronejad  |e author 
245 0 0 |a Evaluation of torque loss value of MAD/MAM zirconia abutments with prefabricated titanium abutments 
260 |b Tehran University of Medical Sciences,   |c 2013-04-01T00:00:00Z. 
500 |a 1024-641X 
500 |a 2008-2444 
520 |a Background and Aims: In response to esthetic demand of patients, ceramic abutments have been developed. Despite esthetic of zirconia abutments, machining accuracy of these abutments has always been a question. Any misfit in the abutment-implant interface connection can lead to detorque and screw loosening. The aim of this study was to compare torque loss value of manually aided design/manually aided manufacture (MAD/MAM) zirconia abutments with prefabricated titanium abutments. Materials and Methods: Seven titanium abutments (Branemark RP, Easy abutment) and seven copy milled abutments which were duplicated from the prefabricated Zirkonzhan (ZirkonZahn, Sand in Taufers, Italy) were prepared. After sintering process of zirconia abutment, all abutments were fastened with a torque screw under 35 Ncm. Detorque measurements were performed per group pushing the reverse button of the Torque controller soon after screw tightening with values registered. The mean torque loss were calculated and compared using Student's t test. Results: The mean of torque loss was 12.71 Ncm with standard deviation of 1.70 for prefabricated titanium abutments and 15.50 Ncm with standard deviation of 4.67 for MAD-MAM abutments. The difference between the two groups was not statistically significant (P=0.23). Conclusion: Within the limitation of this study, MAD-MAM ceramic abutments could maintain the applied torque comparing to the prefabricated abutments. 
546 |a FA 
690 |a Torque loss 
690 |a Zirconia abutment 
690 |a Titanium abutment 
690 |a Medicine 
690 |a R 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Journal of Dental Medicine, Vol 26, Iss 1, Pp 48-54 (2013) 
787 0 |n http://jdm.tums.ac.ir/browse.php?a_code=A-10-25-7&slc_lang=en&sid=1 
787 0 |n https://doaj.org/toc/1024-641X 
787 0 |n https://doaj.org/toc/2008-2444 
856 4 1 |u https://doaj.org/article/4edabc608ceb47cda2b56f04f9fa93b6  |z Connect to this object online.