The Comparison of Sensitivity and Specificity of ELISA-based Microneutralization Test with Hemagglutination Inhibition Test to Evaluate Neutralizing Antibody against Influenza Virus (H1N1)

Background: The most common serological assay to measure anti-influenza antibodies is hemagglutination inhibition (HI) assay. Recently, neutralizing antibodies against influenza virus infection or vaccination can also be detected using microneutralization assays and occasionally, have greater sensit...

Full description

Saved in:
Bibliographic Details
Main Authors: Ahmad TAVAKOLI (Author), Farhad REZAEI (Author), Gazal Sadat FATEMI NASAB (Author), Fatemeh ADJAMINEZHAD-FARD (Author), Zahra NOROOZBABAEI (Author), Talat MOKHTARI-AZAD (Author)
Format: Book
Published: Tehran University of Medical Sciences, 2017-11-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_4f29a57ca1094e80b4e7bd059e16069b
042 |a dc 
100 1 0 |a Ahmad TAVAKOLI  |e author 
700 1 0 |a Farhad REZAEI  |e author 
700 1 0 |a Gazal Sadat FATEMI NASAB  |e author 
700 1 0 |a Fatemeh ADJAMINEZHAD-FARD  |e author 
700 1 0 |a Zahra NOROOZBABAEI  |e author 
700 1 0 |a Talat MOKHTARI-AZAD  |e author 
245 0 0 |a The Comparison of Sensitivity and Specificity of ELISA-based Microneutralization Test with Hemagglutination Inhibition Test to Evaluate Neutralizing Antibody against Influenza Virus (H1N1) 
260 |b Tehran University of Medical Sciences,   |c 2017-11-01T00:00:00Z. 
500 |a 2251-6085 
500 |a 2251-6093 
520 |a Background: The most common serological assay to measure anti-influenza antibodies is hemagglutination inhibition (HI) assay. Recently, neutralizing antibodies against influenza virus infection or vaccination can also be detected using microneutralization assays and occasionally, have greater sensitivity than the standard HI assays. The study aimed to compare the sensitivity and specificity of ELISA-based microneutralization (microNT-ELISA) and conventional HI assays in order to detect influenza H1N1 virus antibodies. Methods: MicroNT-ELISA was set up according to the WHO Manual on Influenza Diagnosis and Surveillance in Virology Department of Tehran University of Medical Sciences for the detection of neutralizing antibodies against H1N1 influenza virus in 2013. Fifty serum samples were analyzed with both HI and microNT-ELISA assays. Correlation between methods was calculated by linear regression analysis. Results: The linear correlation coefficient squares, R2, of microNT-ELISA and HI test was 0.61 (P<0.0001) and we observed a high index of coincidence between the two tests. According to McNemar's test, there was no statistically significant difference between these two assays (P>0.05). Conclusion: The sensitivity and specificity of microNT-ELISA assay were high (87% and 73%, respectively) and closely related to gold standard test results. Therefore, microNT-ELISA is recommended as an alternative or complementary test to conventional HI assay for serological and epidemiological purposes. 
546 |a EN 
690 |a Microneutralization assay 
690 |a MicroNT-ELISA 
690 |a Hemagglutination inhibition assay 
690 |a Influenza virus 
690 |a Serological assays 
690 |a Public aspects of medicine 
690 |a RA1-1270 
655 7 |a article  |2 local 
786 0 |n Iranian Journal of Public Health, Vol 46, Iss 12 (2017) 
787 0 |n https://ijph.tums.ac.ir/index.php/ijph/article/view/11767 
787 0 |n https://doaj.org/toc/2251-6085 
787 0 |n https://doaj.org/toc/2251-6093 
856 4 1 |u https://doaj.org/article/4f29a57ca1094e80b4e7bd059e16069b  |z Connect to this object online.