Adsorption of Cu2+ Ions From Aqueous Solutions Using Oxidized Multi-Walled Carbon Nanotubes

Copper ion (Cu2+) is one of the heavy metal ions that cause environmental pollution specifically in water. Copper ion cations are not biodegradable and tend to cumulate in living organisms. Consequently, the removal of Cu2+ in environmental samples plays an important role in environmental pollution...

Full description

Saved in:
Bibliographic Details
Main Authors: Soheil Sobhanardakani (Author), Raziyeh Zandipak (Author), Mehrdad Cheraghi (Author)
Format: Book
Published: Hamadan University of Medical Sciences, 2015-06-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_57a0c1adf13d4abe9421c3c005aef9f6
042 |a dc 
100 1 0 |a Soheil Sobhanardakani  |e author 
700 1 0 |a Raziyeh Zandipak  |e author 
700 1 0 |a Mehrdad Cheraghi  |e author 
245 0 0 |a Adsorption of Cu2+ Ions From Aqueous Solutions Using Oxidized Multi-Walled Carbon Nanotubes 
260 |b Hamadan University of Medical Sciences,   |c 2015-06-01T00:00:00Z. 
500 |a 2423-4583 
500 |a 10.17795/ajehe790 
520 |a Copper ion (Cu2+) is one of the heavy metal ions that cause environmental pollution specifically in water. Copper ion cations are not biodegradable and tend to cumulate in living organisms. Consequently, the removal of Cu2+ in environmental samples plays an important role in environmental pollution monitoring. The purpose of the present work was to prepare oxidized Multi-Walled Carbon Nano Tubes (MWCNTs) for removal of Cu2+ ions from aqueous solutions. This study was conducted under laboratory conditions. Multi-Walled Carbon Nano Tubes were oxidized and characterized by Fourier Transform Infrared Spectroscopy (FTIR), Scanning Electron Microscope (SEM) and the Brunauer, Emmett, and Teller (BET) methods. The effects of various factors, such as solution pH (3 - 9), adsorbent dose (0.006 - 0.06 g) and contact time (10 - 120 minutes) were investigated. Results showed that the suitable pH for Cu2+ ions removal was about 6.0, and the optimal dose was 0.03 g. Isotherm studies indicated that the Langmuir model fits the experimental data better than the Freundlich model. Maximum Cu2+ adsorption capacity was calculated as 200 mg g-1. The kinetics of the adsorption process was tested for the pseudo-first-order and pseudo-second-order models. The comparison among the models showed that the pseudo-second order model best described the adsorption kinetics. The results showed that oxidized MWCNTs can be used as a low cost adsorbent for the removal of Cu2+ ions from aqueous solutions. 
546 |a EN 
690 |a Environmental sciences 
690 |a GE1-350 
690 |a Public aspects of medicine 
690 |a RA1-1270 
655 7 |a article  |2 local 
786 0 |n Avicenna Journal of Environmental Health Engineering, Vol 2, Iss 1 (2015) 
787 0 |n http://dx.doi.org/10.17795/ajehe790 
787 0 |n https://doaj.org/toc/2423-4583 
856 4 1 |u https://doaj.org/article/57a0c1adf13d4abe9421c3c005aef9f6  |z Connect to this object online.