Practice of standard monitoring during anaesthesia in hospitals of North Kivu: a survey of health facilities of the health antenna of Butembo

Abstract Background Standard monitoring during anaesthesia is a core element of patient safety and practice of safe anesthesia has reduced morbidity and mortality worldwide. The main objective of this study was to assess the practice of standard monitoring during anaesthesia in the hospitals of Nort...

Full description

Saved in:
Bibliographic Details
Main Authors: Furaha Nzanzu Blaise Pascal (Author), Paulin Kambale Musavuli (Author), Joel Kambale Ketha (Author), Franck Katembo Sikakulya (Author), Andreas Barratt-Due (Author), Thomas Castner (Author), Gregor Pollach (Author)
Format: Book
Published: BMC, 2020-03-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_588b50b54b0a4cf8b79bab4c1d5c302c
042 |a dc 
100 1 0 |a Furaha Nzanzu Blaise Pascal  |e author 
700 1 0 |a Paulin Kambale Musavuli  |e author 
700 1 0 |a Joel Kambale Ketha  |e author 
700 1 0 |a Franck Katembo Sikakulya  |e author 
700 1 0 |a Andreas Barratt-Due  |e author 
700 1 0 |a Thomas Castner  |e author 
700 1 0 |a Gregor Pollach  |e author 
245 0 0 |a Practice of standard monitoring during anaesthesia in hospitals of North Kivu: a survey of health facilities of the health antenna of Butembo 
260 |b BMC,   |c 2020-03-01T00:00:00Z. 
500 |a 10.1186/s12913-020-05076-x 
500 |a 1472-6963 
520 |a Abstract Background Standard monitoring during anaesthesia is a core element of patient safety and practice of safe anesthesia has reduced morbidity and mortality worldwide. The main objective of this study was to assess the practice of standard monitoring during anaesthesia in the hospitals of North Kivu, so as to establish a baseline overview of the situation, and orientate plans towards safe anaesthesia in the region. Methods This study was a cross-sectional survey of health facilities of the Health Antenna of Butembo in Democratic Republic of Congo and was conducted from October to December 2018. Questionnaires were brought to anaesthesia providers in the health facilities. The study included 1 answer from the anaesthesia practitioners who accepted to participate. The practices of standard monitoring in the health facilities were compared to WHO-WSFA guidelines. Data was captured and analyzed with Epi Info 7. Results Forty out of 90 health facilities (44.4%) of 10 health zones responded on the questionnaire. Twenty-three health facilities (57.5%) were from private sector and 17 (42.5%) from public sector. Sixteen health facilities (40.0%) were from the Butembo health zone. The median number of anaesthesia providers was 2 per health facility. Of all the anaesthesia providers, none were physicians, 47.5% were nurses practicing anaesthesia without any training in anaesthesia and 47.5% were nurse anaesthetists. All the health facilities were providing general anaesthesia whereas spinal anaesthesia was provided in 22 out of 40 centers (55%). Seventy percent (28/40) of the facilities were below standard according to WHO-WSFA guidelines. Only 40% (16/40) were using a pulse oximeter and 10% (4/40) declared that ECG was occasionally used. Conclusion The practice of standard monitoring is poor in health facilities of the Health Antenna of Butembo. Efforts should be made to improve monitoring which is a key element of safe anaesthesia. 
546 |a EN 
690 |a Public aspects of medicine 
690 |a RA1-1270 
655 7 |a article  |2 local 
786 0 |n BMC Health Services Research, Vol 20, Iss 1, Pp 1-8 (2020) 
787 0 |n http://link.springer.com/article/10.1186/s12913-020-05076-x 
787 0 |n https://doaj.org/toc/1472-6963 
856 4 1 |u https://doaj.org/article/588b50b54b0a4cf8b79bab4c1d5c302c  |z Connect to this object online.