Real-Time Monitoring System Based on Li-Fi Network Technology in Healthcare
Patients at healthcare facilities require a long-term continuous healthcare monitoring system to keep track of their vital signs. Because it deals with human life, this system must be safe, trustworthy, and ensure that it does not interfere with available radio frequencies or sensitive electronic de...
Saved in:
Main Authors: | , |
---|---|
Format: | Book |
Published: |
College of Education for Pure Sciences,
2021-09-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_58b008b856064c198c4afd1dc6dbaea3 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Yasser Nozad |e author |
700 | 1 | 0 | |a Ayad Mohammedtawfiq |e author |
245 | 0 | 0 | |a Real-Time Monitoring System Based on Li-Fi Network Technology in Healthcare |
260 | |b College of Education for Pure Sciences, |c 2021-09-01T00:00:00Z. | ||
500 | |a 1812-125X | ||
500 | |a 2664-2530 | ||
500 | |a 10.33899/edusj.2021.130106.1159 | ||
520 | |a Patients at healthcare facilities require a long-term continuous healthcare monitoring system to keep track of their vital signs. Because it deals with human life, this system must be safe, trustworthy, and ensure that it does not interfere with available radio frequencies or sensitive electronic devices such as MRI (magnetic resonance imaging). This paper introduces a patient monitoring system in intensive care that used Li-Fi technology, designed to help enhance patient care and boost doctor's clinical results. This robust approach timely collects patient data and integrates securely within the hospital IT framework feeding information to physicians, allowing them to make informed clinical decisions. The system used real-time software which displays the data from different locations for assessment. It was successfully tested in the laboratory. Some measurements are discussed, which compare the received pulses to the modules line of sight (LOS) output channel to correlate the transmitted channels. In this work, experimental analysis and measurements are performed to check the efficiency of the proposed concept. | ||
546 | |a AR | ||
546 | |a EN | ||
690 | |a li-fi technology,, | ||
690 | |a ,،,؛e-health shield kit,, | ||
690 | |a ,،,؛vlc | ||
690 | |a Education | ||
690 | |a L | ||
690 | |a Science (General) | ||
690 | |a Q1-390 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n مجلة التربية والعلم, Vol 30, Iss 4, Pp 193-200 (2021) | |
787 | 0 | |n https://edusj.mosuljournals.com/article_168638_7167e0e6f52bd0c05b98e351cd03909e.pdf | |
787 | 0 | |n https://doaj.org/toc/1812-125X | |
787 | 0 | |n https://doaj.org/toc/2664-2530 | |
856 | 4 | 1 | |u https://doaj.org/article/58b008b856064c198c4afd1dc6dbaea3 |z Connect to this object online. |