Real-Time Monitoring System Based on Li-Fi Network Technology in Healthcare

Patients at healthcare facilities require a long-term continuous healthcare monitoring system to keep track of their vital signs. Because it deals with human life, this system must be safe, trustworthy, and ensure that it does not interfere with available radio frequencies or sensitive electronic de...

Full description

Saved in:
Bibliographic Details
Main Authors: Yasser Nozad (Author), Ayad Mohammedtawfiq (Author)
Format: Book
Published: College of Education for Pure Sciences, 2021-09-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_58b008b856064c198c4afd1dc6dbaea3
042 |a dc 
100 1 0 |a Yasser Nozad  |e author 
700 1 0 |a Ayad Mohammedtawfiq  |e author 
245 0 0 |a Real-Time Monitoring System Based on Li-Fi Network Technology in Healthcare 
260 |b College of Education for Pure Sciences,   |c 2021-09-01T00:00:00Z. 
500 |a 1812-125X 
500 |a 2664-2530 
500 |a 10.33899/edusj.2021.130106.1159 
520 |a Patients at healthcare facilities require a long-term continuous healthcare monitoring system to keep track of their vital signs. Because it deals with human life, this system must be safe, trustworthy, and ensure that it does not interfere with available radio frequencies or sensitive electronic devices such as MRI (magnetic resonance imaging). This paper introduces a patient monitoring system in intensive care that used Li-Fi technology, designed to help enhance patient care and boost doctor's clinical results. This robust approach timely collects patient data and integrates securely within the hospital IT framework feeding information to physicians, allowing them to make informed clinical decisions. The system used real-time software which displays the data from different locations for assessment. It was successfully tested in the laboratory. Some measurements are discussed, which compare the received pulses to the modules line of sight (LOS) output channel to correlate the transmitted channels. In this work, experimental analysis and measurements are performed to check the efficiency of the proposed concept. 
546 |a AR 
546 |a EN 
690 |a li-fi technology,, 
690 |a ,،,؛e-health shield kit,, 
690 |a ,،,؛vlc 
690 |a Education 
690 |a L 
690 |a Science (General) 
690 |a Q1-390 
655 7 |a article  |2 local 
786 0 |n مجلة التربية والعلم, Vol 30, Iss 4, Pp 193-200 (2021) 
787 0 |n https://edusj.mosuljournals.com/article_168638_7167e0e6f52bd0c05b98e351cd03909e.pdf 
787 0 |n https://doaj.org/toc/1812-125X 
787 0 |n https://doaj.org/toc/2664-2530 
856 4 1 |u https://doaj.org/article/58b008b856064c198c4afd1dc6dbaea3  |z Connect to this object online.