The Effect of Various Bur Types and Two Bonding Agents on Shear Bond Strength of Composite Resin to Dentin

The aims of this in vitro study was to assess the effectiveness of various bur types and bonding agents on the shear bond strength of composite resin to dentin. Eighty non carious, extracted human molars were mounted in acrylic resin, the occlusal surface of all the teeth were grounded to obtain fla...

Full description

Saved in:
Bibliographic Details
Main Author: Wiaam M AL-Ashou (Author)
Format: Book
Published: University of Mosul, College of Dentistry, 2012-08-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_5975c62eb34b45c0b3bc742d3dd2f70b
042 |a dc 
100 1 0 |a Wiaam M AL-Ashou  |e author 
245 0 0 |a The Effect of Various Bur Types and Two Bonding Agents on Shear Bond Strength of Composite Resin to Dentin 
260 |b University of Mosul, College of Dentistry,   |c 2012-08-01T00:00:00Z. 
500 |a 10.33899/rden.2012.65070 
500 |a 1812-1217 
500 |a 1998-0345 
520 |a The aims of this in vitro study was to assess the effectiveness of various bur types and bonding agents on the shear bond strength of composite resin to dentin. Eighty non carious, extracted human molars were mounted in acrylic resin, the occlusal surface of all the teeth were grounded to obtain flat dentin surface. After that the teeth were randomly divided into four groups (n=20) according to the bur types that will be used to prepare the dentin surface. After preparation of dentin each group was divided into two subgroups (n=10) according to the type of adhesive systems used (Excite & I-Bond), the adhesive systems were applied to the dentin surface and light-cured according to manufacturers instructions. A 4mm high composite cylinder was incrementally built up. After that, specimens stored for one month at 37ºc in distilled water and thermo cycled for 500 cycles between (5ºc & 55ºc) and then tested in a universal testing machine. The results of this study demonstrated that the method of surface prepa-ration affected the shear bond strength of I-Bond and this is not true for Exit system, when the dentin surface prepared with fissure burs the shear bond strength greater than when the surface prepared with round burs. The results of this study also showed that the groups in which Excite bonding agent used have greater value of shear bond than the groups treated with I-Bond. 
546 |a AR 
546 |a EN 
690 |a dental burs 
690 |a bonding agents 
690 |a shear bond 
690 |a composite resin 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Al-Rafidain Dental Journal, Vol 12, Iss 2, Pp 242-248 (2012) 
787 0 |n https://rden.mosuljournals.com/pdf_65070_685cc0d5fa8aa26ffb2b6c7e8d0ee617.html 
787 0 |n https://doaj.org/toc/1812-1217 
787 0 |n https://doaj.org/toc/1998-0345 
856 4 1 |u https://doaj.org/article/5975c62eb34b45c0b3bc742d3dd2f70b  |z Connect to this object online.