Validated stability-indicating RP-HPLC assay method for fesoterodine fumarate in pharmaceutical products

The goal of the current study was to develop a precise, sensitive and validated reverse phase HPLC method for determination of fesoterodine fumarate (FST). The current investigation was performed for a stability indicating method in order to obtain both assay and impurity profiles of FST. All the ex...

पूर्ण विवरण

में बचाया:
ग्रंथसूची विवरण
मुख्य लेखकों: Onur PINARBASLI (लेखक), Tolga OZBAY (लेखक), Gulistan Pelin GURBETOGLU (लेखक), Nagehan SARRACOGLU (लेखक), Asuman DOGANAY (लेखक)
स्वरूप: पुस्तक
प्रकाशित: Polskie Towarzystwo Farmaceutyczne, 2023-05-01T00:00:00Z.
विषय:
ऑनलाइन पहुंच:Connect to this object online.
टैग: टैग जोड़ें
कोई टैग नहीं, इस रिकॉर्ड को टैग करने वाले पहले व्यक्ति बनें!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_5adbaf5b014e4e9fb49b2f4b25c1e420
042 |a dc 
100 1 0 |a Onur PINARBASLI  |e author 
700 1 0 |a Tolga OZBAY  |e author 
700 1 0 |a Gulistan Pelin GURBETOGLU  |e author 
700 1 0 |a Nagehan SARRACOGLU  |e author 
700 1 0 |a Asuman DOGANAY  |e author 
245 0 0 |a Validated stability-indicating RP-HPLC assay method for fesoterodine fumarate in pharmaceutical products 
260 |b Polskie Towarzystwo Farmaceutyczne,   |c 2023-05-01T00:00:00Z. 
500 |a 0001-6837 
500 |a 10.32383/appdr/163015 
520 |a The goal of the current study was to develop a precise, sensitive and validated reverse phase HPLC method for determination of fesoterodine fumarate (FST). The current investigation was performed for a stability indicating method in order to obtain both assay and impurity profiles of FST. All the experiment was done on HPLC Shimadzu Prominence 20A having stainless steel ACE5 C18 column with a particle size of 5µm and a dimension of 4.6 mm X 150 mm. The mobile phase was in gradient mode with mobile phase A (0.03M ammonium acetate buffer : acetonitrile : methanol (55:30:15 v/v) pH 3.8) and mobile phase B (water) . The flow rate was 1.2 mL/min and the wavelength 208 nm was selected for detection. This method was validated for linearity and range, accuracy, precision and robustness in accordance with ICH requirements. The retention time of fesoterodine was found as 11.0 min. The main degradation product 5-hydroxymethyltolterodine (5-HMT; active metabolite of FST) and the other process impurities; aldehyde, benzylated hydroxy, tolterodine ester, diester impurities were detected easily at the retention times 3.8, 13.5, 16.7, 21.5, 37.1 minutes, respectively. It was observed that the retention times of the main peak and its impurities were not affected and the selectivity of the method was proved under the applied stress conditions. With this developed method, FST and its impurities can easily be detected. It is also stable, simple, accurate, and completely validated RP-HPLC technique for the analysis of FST and related impurities that meets with ICH standards. 
546 |a EN 
690 |a tablets 
690 |a validation 
690 |a rp-hplc 
690 |a fesoterodine fumarate 
690 |a stability-indicating method 
690 |a Pharmacy and materia medica 
690 |a RS1-441 
655 7 |a article  |2 local 
786 0 |n Acta Poloniae Pharmaceutica, Vol 80, Iss 1, Pp 33-43 (2023) 
787 0 |n https://www.ptfarm.pl/download/?file=File%2FActa_Poloniae%2F2023%2F1%2F033.pdf 
787 0 |n https://doaj.org/toc/0001-6837 
856 4 1 |u https://doaj.org/article/5adbaf5b014e4e9fb49b2f4b25c1e420  |z Connect to this object online.