The Bactericidal Effect Of Erbium, Chromium: Yttrium Scandium Gallium Garnet Laser On Contaminated SandBlasted, Large Grit, Acid-Etched Dental

Aims: The purpose of this study was to estimate the bactericidal effect of erbium,chromium:yttrium scandium gallium garnet 2,780nm (Er, Cr:YSGG) on contaminated sand-blasted, large grit, acid-etched (SLA) dental implant and determine the parameter that effectively detoxify the surface of implant ail...

Full description

Saved in:
Bibliographic Details
Main Authors: Abdul Hameed N. Aldabagh (Author), Mohammed K. Hassouni (Author)
Format: Book
Published: University of Mosul, College of Dentistry, 2016-04-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_5d0d4269e8784f14b83c80b1e4afb885
042 |a dc 
100 1 0 |a Abdul Hameed N. Aldabagh  |e author 
700 1 0 |a Mohammed K. Hassouni   |e author 
245 0 0 |a The Bactericidal Effect Of Erbium, Chromium: Yttrium Scandium Gallium Garnet Laser On Contaminated SandBlasted, Large Grit, Acid-Etched Dental 
260 |b University of Mosul, College of Dentistry,   |c 2016-04-01T00:00:00Z. 
500 |a 10.33899/rden.2016.160865 
500 |a 1812-1217 
500 |a 1998-0345 
520 |a Aims: The purpose of this study was to estimate the bactericidal effect of erbium,chromium:yttrium scandium gallium garnet 2,780nm (Er, Cr:YSGG) on contaminated sand-blasted, large grit, acid-etched (SLA) dental implant and determine the parameter that effectively detoxify the surface of implant ailed with periimplantitis before regenerative therapy of the area. Material and Methods: Implants (3.4*10mm) with SLA surfaces fixed with Enterococcus faecalis and irradiated with Er,Cr:YSGG lasers. After laser treatments, the number of remaining colony-forming units (CFUs) counted. The entire implant surface exposed uniformly in constant time and different energies. six powers were used ( 0.25, 0.5, 0.75, 1, 1.25, 1.5watt ) at 20 Hz, water 20%, air 40% with movable motions on each thread for 30 second and in non contact mode at 2 mm distance between MZ10 tip and target with H mode. Results: laser showed total bacteria reduction on the implants irradiated with 1.5W. Significant differences between measurements in the different groups at (P<0.05) were observed, depending on the used power. Conclusions: Er,Cr:YSGGlaser can be used at above parameter safelyon implant surface as disinfection tool in treatment of peri-implantitis 
546 |a AR 
546 |a EN 
690 |a er 
690 |a cr:ysgg laser 
690 |a dental implant 
690 |a peri-implantitis. 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Al-Rafidain Dental Journal, Vol 16, Iss 1, Pp 67-76 (2016) 
787 0 |n https://rden.mosuljournals.com/pdf_160865_4faa06247b06d2063c22341876f70ef8.html 
787 0 |n https://doaj.org/toc/1812-1217 
787 0 |n https://doaj.org/toc/1998-0345 
856 4 1 |u https://doaj.org/article/5d0d4269e8784f14b83c80b1e4afb885  |z Connect to this object online.