The influence of different screw tightening forces on the vertical misfit of implant-supported frameworks Avaliação do efeito da força de aperto de parafusos de retenção na desadaptação marginal de próteses sobre implantes
OBJECTIVES: The present in vitro study was designed to compare the differences in the vertical misfit of implant-supported frameworks using three different forces for tightening the bridge locking screws: fastening by hand until first resistance, and using torque drivers with 10 and 20Ncm. METHODS:...
Guardado en:
Autores principales: | , , , , |
---|---|
Formato: | Libro |
Publicado: |
University of São Paulo,
2005-06-01T00:00:00Z.
|
Materias: | |
Acceso en línea: | Connect to this object online. |
Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_60e4e6fa3f0147fc8b3ab70bf464c073 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Diego Klee de Vasconcellos |e author |
700 | 1 | 0 | |a Marco Antonio Bottino |e author |
700 | 1 | 0 | |a Renato Sussumu Nishioka |e author |
700 | 1 | 0 | |a Luiz Felipe Valandro |e author |
700 | 1 | 0 | |a Elza Maria Valadares da Costa |e author |
245 | 0 | 0 | |a The influence of different screw tightening forces on the vertical misfit of implant-supported frameworks Avaliação do efeito da força de aperto de parafusos de retenção na desadaptação marginal de próteses sobre implantes |
260 | |b University of São Paulo, |c 2005-06-01T00:00:00Z. | ||
500 | |a 10.1590/S1678-77572005000200005 | ||
500 | |a 1678-7757 | ||
500 | |a 1678-7765 | ||
520 | |a OBJECTIVES: The present in vitro study was designed to compare the differences in the vertical misfit of implant-supported frameworks using three different forces for tightening the bridge locking screws: fastening by hand until first resistance, and using torque drivers with 10 and 20Ncm. METHODS: The investigation was conducted based on the results given by 9 six-unit nickel-chromium (2 abutments/ 4 pontics) screw-retained implant-supported frameworks. The structures were exposed to simulated porcelain firings. The marginal misfit measurements were made using a traveling measuring microscope at selected screw tightening forces: fastening by hand until first resistance, and using torque drivers with 10 and 20Ncm. The results were submitted to one-way ANOVA with repeated measures on one factor, and post hoc pairwise comparisons using Tukey test (5%). RESULTS: The mean marginal misfit of the frameworks, fastening the screws by hand until first resistance, was 41.56µm (SD±12.45µm). The use of torque driver devices caused a significant reduction in marginal opening (p<0.05). With the lowest torque available (10Ncm), the mean marginal discrepancy at the abutment-framework interface was reduced an average of 52% to a mean marginal opening of 19.71µm (SD±2.97µm). After the use of the 20Ncm torque driver, the mean marginal discrepancy of the frameworks was reduced an average of 69% to a mean marginal opening of 12.82µm (SD±4.0µm). Comparing the use of torque drivers with 10 and 20 Ncm torque, the means are not significantly different from one another. CONCLUSION: The seating force has an important effect on the vertical misfit measurements, once it may considerably narrow the vertical misfit gaps at the abutment-framework interface, thus leading to a misjudgment of the real marginal situation.<br>O presente estudo avaliou o efeito da força de aperto de parafusos de retenção na desadaptação marginal de próteses sobre implantes. A investigação foi conduzida baseada em resultados fornecidos por nove estruturas metálicas implanto-suportadas de seis elementos (02 retentores e 04 pônticos), retidas por parafusos. A mensuração da desadaptação marginal foi realizada com auxílio de microscópio óptico, nos seguintes momentos: M1: aperto com chave manual até a primeira resistência do parafuso; M2: aperto utilizando torquímetro mecânico com 10Ncm e M3: aperto utilizando torquímetro mecânico com 20Ncm. As médias de desadaptação foram submetidas à análise estatística (ANOVA e Tukey). O emprego de torquímetros mecânicos, independente do valor de torque, determinou redução significativa na abertura marginal (p<0,05). A desadaptação média na interface conexão/prótese em M1 foi de 41,56µm (DP±12,45µm). O emprego do torquímetro de 10Ncm (M2), reduziu 52% desta fenda marginal, para uma média de desadaptação de 19,71µm (DP±2,97µm); enquanto o torquímetro de 20Ncm (M3) reduziu 69% da desadaptação marginal, para uma média de 12,82µm (DP±4,0µm) os de retenção de próteses implanto-suportadas tem importante efeito na mensuração da desadaptação marginal, uma vez que pode modificar consideravelmente as aberturas na interface conexão/prótese. | ||
546 | |a EN | ||
690 | |a Implantes dentários | ||
690 | |a Osseointegração | ||
690 | |a Prótese dentária fixada por implante | ||
690 | |a Torque | ||
690 | |a desadaptação | ||
690 | |a Dental implants | ||
690 | |a Osseointegration | ||
690 | |a Implant-supported dental prosthesis | ||
690 | |a Torque | ||
690 | |a misfit | ||
690 | |a Dentistry | ||
690 | |a RK1-715 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n Journal of Applied Oral Science, Vol 13, Iss 2, Pp 120-125 (2005) | |
787 | 0 | |n http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572005000200005 | |
787 | 0 | |n https://doaj.org/toc/1678-7757 | |
787 | 0 | |n https://doaj.org/toc/1678-7765 | |
856 | 4 | 1 | |u https://doaj.org/article/60e4e6fa3f0147fc8b3ab70bf464c073 |z Connect to this object online. |