Influence of the type of reciprocating motion on the cyclic fatigue resistance of reciprocating files in a dynamic model

Abstract Background The aim of this study was to compare the influence of two novel reciprocating movements on the cyclic fatigue resistance of endodontic reciprocating files. Methods 30 Procodile® (Komet Medical, Lemgo, Germany) files were selected in this study and distributed according to the fol...

Full description

Saved in:
Bibliographic Details
Main Authors: Álvaro Zubizarreta-Macho (Author), Alberto Albaladejo Martínez (Author), Carlos Falcão Costa (Author), Norberto Quispe-López (Author), Ruben Agustín-Panadero (Author), Jesús Mena-Álvarez (Author)
Format: Book
Published: BMC, 2021-04-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_61f5cd6d003f447ab00c899f29b2c20a
042 |a dc 
100 1 0 |a Álvaro Zubizarreta-Macho  |e author 
700 1 0 |a Alberto Albaladejo Martínez  |e author 
700 1 0 |a Carlos Falcão Costa  |e author 
700 1 0 |a Norberto Quispe-López  |e author 
700 1 0 |a Ruben Agustín-Panadero  |e author 
700 1 0 |a Jesús Mena-Álvarez  |e author 
245 0 0 |a Influence of the type of reciprocating motion on the cyclic fatigue resistance of reciprocating files in a dynamic model 
260 |b BMC,   |c 2021-04-01T00:00:00Z. 
500 |a 10.1186/s12903-021-01538-8 
500 |a 1472-6831 
520 |a Abstract Background The aim of this study was to compare the influence of two novel reciprocating movements on the cyclic fatigue resistance of endodontic reciprocating files. Methods 30 Procodile® (Komet Medical, Lemgo, Germany) files were selected in this study and distributed according to the following study groups depending on the movements to be performed: ReFlex Dynamic (n = 10), ReFlex Smart (n = 10) and Reciproc (n = 10) reciprocating movement. These files were fixed to a specific dynamic cyclic fatigue device designed and manufactured by 3D impression to simulate the pecking motion performed by the operator. The time to failure and the number of cycles of in-and-out of the endodontic files was registered. The results were analyzed by ANOVA and Weibull statistics. Results Statistically significant differences were found when the number of cycles of in-and-out movement and the time to failure of ReFlex Dynamic and Reciproc reciprocating movement (p < 0.001) and between ReFlex Smart and Reciproc reciprocating movement (p < 0.001) were compared in pairs. However, no statistically significant differences were observed between time to failure and number of cycles of in-and-out movement of ReFlex Dynamic and ReFlex Smart reciprocating movement (p = 0.253). Conclusions The ReFlex Smart reciprocating movement increased the cyclic fatigue resistance of endodontic reciprocating files compared with traditional reciprocating movement. 
546 |a EN 
690 |a Endodontics 
690 |a Cyclic fatigue 
690 |a Nitinol 
690 |a Reciprocating movement 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n BMC Oral Health, Vol 21, Iss 1, Pp 1-10 (2021) 
787 0 |n https://doi.org/10.1186/s12903-021-01538-8 
787 0 |n https://doaj.org/toc/1472-6831 
856 4 1 |u https://doaj.org/article/61f5cd6d003f447ab00c899f29b2c20a  |z Connect to this object online.