Effect of Inter-pupillary Distance on Stereo-acuity
Objective: To determine the effect of interpupillary distance (IPD) on stereopsis and to compare this affect in male and female population. Methodology: Descriptive cross-sectional study was conducted on 30 individuals of either gender with age ranging from 15 to 30 years. Sample was recruited by no...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Book |
Published: |
Aziz Fatimah Medical and Dental College,
2019-04-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_65e76e01b45d4402a4c3a55fa867a9c8 | ||
042 | |a dc | ||
100 | 1 | 0 | |a Fatima Iqbal |e author |
700 | 1 | 0 | |a Komal Atta |e author |
700 | 1 | 0 | |a Hashim Ali Khan |e author |
700 | 1 | 0 | |a Amna Iqbal |e author |
245 | 0 | 0 | |a Effect of Inter-pupillary Distance on Stereo-acuity |
260 | |b Aziz Fatimah Medical and Dental College, |c 2019-04-01T00:00:00Z. | ||
500 | |a 10.55279/jafmdc.v1i1.30 | ||
500 | |a 2706-7238 | ||
500 | |a 2706-7246 | ||
520 | |a Objective: To determine the effect of interpupillary distance (IPD) on stereopsis and to compare this affect in male and female population. Methodology: Descriptive cross-sectional study was conducted on 30 individuals of either gender with age ranging from 15 to 30 years. Sample was recruited by non-probability convenient sampling technique at Ophthalmology department of Madina Teaching Hospital, Faisalabad from August 2018 to December 2018. Individuals with any ocular pathology, un-corrected refractive error or drug users were excluded. Near IPD was measured using millimeter scale and stereopsis was evaluated using titmus fly test. Data was analyzed by SPSS21. P value ?0.05 was considered significant. Results: Our study comprised of 30 subjects of aged range 15-30 years. 15 participants were male and 15 were females. IPD values for both genders were ranged between 62 - 66 mm. mean IPD was 65± 1.01 mm for male and 64.8± 1.14 mm for female ,no significant difference was observed in mean IPD among gender ( P value = 0.41) by t test. Both male and females have high IPD and low depth of perception (< 40 sec of arc), no significant difference in levels of Stereopsis was noted among gender (P value= 0.36). Pearson's correlation showed significant relation between IPD and stereopsis. (P value= 0000*). Conclusion: We found higher IPD and low depth of perception among both genders. | ||
546 | |a EN | ||
690 | |a Depth perception, Inter-pupillary distance, Stereopsis | ||
690 | |a Dentistry | ||
690 | |a RK1-715 | ||
690 | |a Medicine (General) | ||
690 | |a R5-920 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n Journal of Aziz Fatimah Medical and Dental College, Vol 1, Iss 1 (2019) | |
787 | 0 | |n https://journal.afmdc.edu.pk/index.php/AFMDC/article/view/30 | |
787 | 0 | |n https://doaj.org/toc/2706-7238 | |
787 | 0 | |n https://doaj.org/toc/2706-7246 | |
856 | 4 | 1 | |u https://doaj.org/article/65e76e01b45d4402a4c3a55fa867a9c8 |z Connect to this object online. |