Dimensional accuracy of three impression materials by one-step and two-step impression techniques: An in vitro study
<strong>Introduction:</strong> An accurate impression is essential to create a well-fitted dental prosthesis. This study aimed to compare the dimensional accuracy of three elastomeric materials using one-step and two-step impression techniques. <strong>Methods:</strong> In th...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Book |
Published: |
Mashhad University of Medical Sciences,
2020-03-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | <strong>Introduction:</strong> An accurate impression is essential to create a well-fitted dental prosthesis. This study aimed to compare the dimensional accuracy of three elastomeric materials using one-step and two-step impression techniques. <strong>Methods:</strong> In this study, 20 impressions were fabricated for each Vinyl siloxane ether (Identium), condensation silicone (Speedex), and additional silicone (Panasil) impression materials by the one-step and two-step impression techniques using perforated metal trays. The one-step impression technique was simultaneously performed with heavy body/light-body materials. In the two-step impression technique, acrylic copings with 2-mm thickness were placed on the abutments to obtain similar spacing for the light-body material. The dimensional accuracy of different impression materials and techniques were measured using distance differences of the stone dies from the master cast; subsequently, the results were compared with the reference model. Data were analyzed using a one-way analysis of variance and Dunnett's tests (α=0.05). <strong>Results:</strong> All impression materials demonstrated an acceptable clinical accuracy. Identium (Vinyl siloxane ether) displayed the most accuracy in both the one-step and two-step impression techniques (P>0.05). The best accuracy for Panasil (additional silicone) was found to be the two-step impression technique (P>0.05), and the best accuracy for Speedex (condensation silicone) was reported as the one-step impression technique (P>0.05). Furthermore, the one-step impression technique was highly accurate in diameter dimension, as compared to the two-step impression technique. <strong>Conclusion:</strong> As evidenced by the results, the accuracy of impression is affected by the impression materials. Moreover, Identium (Vinyl siloxane ether) demonstrated the most accuracy in both one-step and two-step impression techniques. |
---|---|
Item Description: | 2322-4150 2252-0317 10.22038/jdmt.2020.43747.1314 |