In Vivo Disintegration of Four Different Luting Agents

The purpose of this study was to evaluate the disintegration of luting agents. An intraoral sample holder was made having four holes of 1.4 mm diameter and 2 mm depth. The holder was soldered onto the buccal surface of an orthodontic band, which was cemented to the first upper molar in 12 patients,...

Full description

Saved in:
Bibliographic Details
Main Authors: Deniz Gemalmaz (Author), Cornelis H. Pameijer (Author), Mark Latta (Author), Ferah Kuybulu (Author), Toros Alcan (Author)
Format: Book
Published: Hindawi Limited, 2012-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_6e17bc52af3c48e8989e3f01b04d0a86
042 |a dc 
100 1 0 |a Deniz Gemalmaz  |e author 
700 1 0 |a Cornelis H. Pameijer  |e author 
700 1 0 |a Mark Latta  |e author 
700 1 0 |a Ferah Kuybulu  |e author 
700 1 0 |a Toros Alcan  |e author 
245 0 0 |a In Vivo Disintegration of Four Different Luting Agents 
260 |b Hindawi Limited,   |c 2012-01-01T00:00:00Z. 
500 |a 1687-8728 
500 |a 1687-8736 
500 |a 10.1155/2012/831508 
520 |a The purpose of this study was to evaluate the disintegration of luting agents. An intraoral sample holder was made having four holes of 1.4 mm diameter and 2 mm depth. The holder was soldered onto the buccal surface of an orthodontic band, which was cemented to the first upper molar in 12 patients, average age 26 years. The holes were filled with a zinc phosphate (Phosphate Kulzer), a glass ionomer (Ketac Cem), a resin-modified-glass ionomer (Fuji Plus), and a resin cement (Calibra). Impressions were made at baseline, and 6, 12, and 18 months from which epoxy replicas were made, which were scanned with an optical scanner. Total volume loss was calculated. The rank order of mean volume loss was as follows: Phosphate cement > Ketac Cem = Fuji Plus = Calibra. Cement type and time had statistically significant effects on volume loss of cements (P<0.001). Under in vivo conditions, zinc phosphate cement disintegrated the most, whereas no significant difference was observed for glass ionomer and resin-based cements. As intraoral conditions are considerably less aggressive than experimental laboratory conditions, the erosion behavior of glass ionomer cement was found to be similar to the resin-based cements in contradiction to previous laboratory results. 
546 |a EN 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n International Journal of Dentistry, Vol 2012 (2012) 
787 0 |n http://dx.doi.org/10.1155/2012/831508 
787 0 |n https://doaj.org/toc/1687-8728 
787 0 |n https://doaj.org/toc/1687-8736 
856 4 1 |u https://doaj.org/article/6e17bc52af3c48e8989e3f01b04d0a86  |z Connect to this object online.