Analisis Intensitas Cahaya di Dalam Ruangan dengan Menggunakan Aplikasi Smart Luxmeter Berbasis Android

The lighting system is very important to pay attention to because our eye health will be disturbed by the lack of light intensity. A room, especially a workspace, must have adequate light following predetermined standards. Analysis of light intensity measurement using a digital lux meter to determin...

Full description

Saved in:
Bibliographic Details
Main Authors: Sheika Ika Putri (Author), Sudarti Sudarti (Author)
Format: Book
Published: Universitas Sebelas Maret, 2022-10-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_6e39d72abfa743a49161670af71490b2
042 |a dc 
100 1 0 |a Sheika Ika Putri  |e author 
700 1 0 |a Sudarti Sudarti  |e author 
245 0 0 |a Analisis Intensitas Cahaya di Dalam Ruangan dengan Menggunakan Aplikasi Smart Luxmeter Berbasis Android 
260 |b Universitas Sebelas Maret,   |c 2022-10-01T00:00:00Z. 
500 |a 2089-6158 
500 |a 2620-3944 
500 |a 10.20961/jmpf.v12i2.51474 
520 |a The lighting system is very important to pay attention to because our eye health will be disturbed by the lack of light intensity. A room, especially a workspace, must have adequate light following predetermined standards. Analysis of light intensity measurement using a digital lux meter to determine the value of light intensity, this experiment was conducted to determine whether the light intensity in the room had or did not meet the standard of SNI 16-7062-2004. The digital lux meter used can measure the light intensity generated from the room prepared using 3-watt LED lights with a room size of 3 × 3 meters. Data retrieval has been done by placing a lux meter in every corner of the room at the same distance between the light source and the lux meter, which is 2 meters. To determine the effectiveness of the light intensity, the measurement results are compared with SNI's lux meter. The experimental data that have been carried out do not meet the SNI requirements for lighting in the workspace, the average intensity value is 12.25 Lux, 153 lumens in 15 seconds uses a calibration of 100%. 
546 |a ID 
690 |a intensity 
690 |a luxmeter 
690 |a comparison 
690 |a light source 
690 |a Physics 
690 |a QC1-999 
690 |a Education 
690 |a L 
655 7 |a article  |2 local 
786 0 |n Jurnal Materi dan Pembelajaran Fisika, Vol 12, Iss 2, Pp 51-55 (2022) 
787 0 |n https://jurnal.uns.ac.id/jmpf/article/view/51474 
787 0 |n https://doaj.org/toc/2089-6158 
787 0 |n https://doaj.org/toc/2620-3944 
856 4 1 |u https://doaj.org/article/6e39d72abfa743a49161670af71490b2  |z Connect to this object online.