Restoration: Implant with Devastated Platform through Metal Post

Case Presentation. Implant prostheses are a successful treatment for replacing missing teeth. However, this treatment modality can have biological and mechanical complications causing serious problems for the dentist, as demonstrated in this clinical case. The patient presented with a fractured scre...

Ful tanımlama

Kaydedildi:
Detaylı Bibliyografya
Asıl Yazarlar: Luna Salinas Tatiana (Yazar), Del Valle Lovato Juan (Yazar)
Materyal Türü: Kitap
Baskı/Yayın Bilgisi: Hindawi Limited, 2017-01-01T00:00:00Z.
Konular:
Online Erişim:Connect to this object online.
Etiketler: Etiketle
Etiket eklenmemiş, İlk siz ekleyin!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_70a6fa71a2e74f418034d7f0a009e09f
042 |a dc 
100 1 0 |a Luna Salinas Tatiana  |e author 
700 1 0 |a Del Valle Lovato Juan  |e author 
245 0 0 |a Restoration: Implant with Devastated Platform through Metal Post 
260 |b Hindawi Limited,   |c 2017-01-01T00:00:00Z. 
500 |a 2090-6447 
500 |a 2090-6455 
500 |a 10.1155/2017/3150656 
520 |a Case Presentation. Implant prostheses are a successful treatment for replacing missing teeth. However, this treatment modality can have biological and mechanical complications causing serious problems for the dentist, as demonstrated in this clinical case. The patient presented with a fractured screw and a severely damaged implant hex connection that corresponded to the second premolar, upper left, stating that she unsuccessfully tried to remove the prosthetic screw, which was most likely to have been loose. After clinical and radiographic review, it was decided to remove small fragments of the fractured prosthetic screw inside the implant head. Removal by conventional methods was unsuccessful but was eventually achieved through use of a bur. Then it was possible to make a cast post (gold-palladium) and develop a fixed prosthesis (silver-palladium), which were attached with luting cement. A cast post (gold-palladium) was made and a fixed prosthesis was developed (silver-palladium), which were attached with luting cement, the same ones that can present mechanical complications such as fractures between the third and fourth thread of the implant, loosening of the abutment, and/or the prosthetic screw in individual crowns, most frequently in partially edentulous patients, mainly in the premolar and molar regions of the maxilla. Conclusion. Therefore the present technique used in this case is very simple, noninvasive, and useful to readers. 
546 |a EN 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Case Reports in Dentistry, Vol 2017 (2017) 
787 0 |n http://dx.doi.org/10.1155/2017/3150656 
787 0 |n https://doaj.org/toc/2090-6447 
787 0 |n https://doaj.org/toc/2090-6455 
856 4 1 |u https://doaj.org/article/70a6fa71a2e74f418034d7f0a009e09f  |z Connect to this object online.