Evaluation of risk factors for catheter-related infections with gram-negative bacteria in Tehran, Iran

Introduction: Catheter infection is due to gram-negative, gram-positive bacteria, and fungi. Gram-positive bacteria are the most prevalent cause of catheter infection, although gram-negative bacteria seem to have escalated in recent years, which may have numerous risk factors. In this report, we int...

Full description

Saved in:
Bibliographic Details
Main Authors: Tahereh Malakoutian (Author), Mehdi Zahmatkesh (Author), Ali Kabir (Author)
Format: Book
Published: Society of Diabetic Nephropathy Prevention, 2022-07-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_718eea906bcc4a2b9c69cb7bed2447d3
042 |a dc 
100 1 0 |a Tahereh Malakoutian  |e author 
700 1 0 |a Mehdi Zahmatkesh  |e author 
700 1 0 |a Ali Kabir  |e author 
245 0 0 |a Evaluation of risk factors for catheter-related infections with gram-negative bacteria in Tehran, Iran 
260 |b Society of Diabetic Nephropathy Prevention,   |c 2022-07-01T00:00:00Z. 
500 |a 2345-4202 
500 |a 10.34172/npj.2022.15 
520 |a Introduction: Catheter infection is due to gram-negative, gram-positive bacteria, and fungi. Gram-positive bacteria are the most prevalent cause of catheter infection, although gram-negative bacteria seem to have escalated in recent years, which may have numerous risk factors. In this report, we intended to study these risk factors. Objectives: This study aimed to investigate the risk factors for catheter-related infections caused by gram-negative bacteria in hemodialysis patients, to prevent catheter-related infections, which are unfortunately abundant. Patients and Methods: This cross-sectional study was conducted on128 hemodialysis patients known cases Hasheminejad hospital in Tehran, Iran in 2019. Patients were assigned into two groups as the case group (catheter-related infection caused by gram-negative bacteria) (n=64) and the control group (catheter-related infection caused by gram-positive bacteria) (n=64). Risk factors for catheter-related infection, including hemoglobin, phosphorus, albumin, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), total iron-binding capacity (TIBC), catheter insertion site, urinary tract infection (UTI), urinary tract manipulation, and urinary tract anomalies were obtained and analyzed via SPSS version 26. Results: Two groups were significantly different in serum albumin level (3.7±0.5 g/dL in gram-negative group and 3.9 ± 0.5 g/dL in gram-positive group; P=0.009) and in UTI (23.4 % in gram-negative group and 7.8 % in gram-positive group; P=0.015). Additionally, no significant differences were observed in serum ferritin, phosphorus, ESR, CRP, TIBC, duration, and site of catheter insertion. Regression analysis shows that, for every unit increase in albumin, the chance of developing a gram-negative catheter infection is 0.356, or about one-third. In other words, with decreasing each unit of albumin, the chance of a gram-negative catheter infection is 2.8 times (reverse 0.356). Conclusion: Serum albumin levels were significantly low in gram-negative group. Moreover, UTIs were significantly higher in this group. It is also important to consider hypoalbuminemia and UTI as risk factors for catheter infection with gram-negative bacteria. 
546 |a EN 
690 |a catheter-related infections 
690 |a vascular catheter 
690 |a hemodialysis 
690 |a gram-negative bacteria 
690 |a gram-positive bacteria 
690 |a Therapeutics. Pharmacology 
690 |a RM1-950 
690 |a Diseases of the genitourinary system. Urology 
690 |a RC870-923 
655 7 |a article  |2 local 
786 0 |n Journal of Nephropharmacology, Vol 11, Iss 2, Pp e15-e15 (2022) 
787 0 |n https://jnephropharmacology.com/PDF/npj-11-e15.pdf 
787 0 |n https://doaj.org/toc/2345-4202 
856 4 1 |u https://doaj.org/article/718eea906bcc4a2b9c69cb7bed2447d3  |z Connect to this object online.