Effect of internal stress on cyclic fatigue failure in .06 taper ProFile

Objectives The purpose of this study was to evaluate the relation between intentionally induced internal stress and cyclic fatigue failure of .06 taper ProFile. Materials and Methods Length 25 mm, .06 taper ProFile (Dentsply Maillefer), and size 20, 25, 30, 35 and 40 were used in this study. To give...

Full description

Saved in:
Bibliographic Details
Main Authors: Hye-Rim Jung (Author), Jin-Woo Kim (Author), Kyung-Mo Cho (Author), Se-Hee Park (Author)
Format: Book
Published: Korean Academy of Conservative Dentistry, 2012-05-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_72a55dc3b0f34a308940f4b52150e77b
042 |a dc 
100 1 0 |a Hye-Rim Jung  |e author 
700 1 0 |a Jin-Woo Kim  |e author 
700 1 0 |a Kyung-Mo Cho  |e author 
700 1 0 |a Se-Hee Park  |e author 
245 0 0 |a Effect of internal stress on cyclic fatigue failure in .06 taper ProFile 
260 |b Korean Academy of Conservative Dentistry,   |c 2012-05-01T00:00:00Z. 
500 |a 10.5395/rde.2012.37.2.79  
500 |a 2234-7658 
500 |a 2234-7666 
520 |a Objectives The purpose of this study was to evaluate the relation between intentionally induced internal stress and cyclic fatigue failure of .06 taper ProFile. Materials and Methods Length 25 mm, .06 taper ProFile (Dentsply Maillefer), and size 20, 25, 30, 35 and 40 were used in this study. To give the internal stress, the rotary NiTi files were put into the .02 taper, Endo-Training-Bloc (Dentsply Maillefer) until auto-stop by torque controlled motor. Rotary NiTi files were grouped by the number of induced internal stress and randomly distributed among one control group and three experimental groups (n = 10, Stress 0 [control], Stress 1, Stress 2 and Stress 3). For cyclic fatigue measurement, time for separation of the rotary NiTi files was recorded. The fractured surfaces were observed by field emission scanning electron microscope (FE-SEM, SU-70, Hitachi). The time for separation was statistically analyzed using two-way ANOVA and post-hoc Scheffe test at 95% level. Results In .06 taper ProFile size 20, 25, 30, 35 and 40, there were statistically significant difference on time for separation between control group and the other groups (p < 0.05). Conclusion In the limitation of this study, cyclic fatigue failure of .06 taper ProFile is influenced by internal stress accumulated in the files. 
546 |a EN 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Restorative Dentistry & Endodontics, Vol 37, Iss 2, Pp 79-83 (2012) 
787 0 |n https://doi.org/10.5395/rde.2012.37.2.79  
787 0 |n https://doaj.org/toc/2234-7658 
787 0 |n https://doaj.org/toc/2234-7666 
856 4 1 |u https://doaj.org/article/72a55dc3b0f34a308940f4b52150e77b  |z Connect to this object online.