Evaluation of the Vmaxpro sensor for assessing movement velocity and load-velocity variables: accuracy and implications for practical use

We investigated the ecological validity of an inertial measurement unit (IMU) (Vmaxpro) to assess the movement velocity (MV) during a 1-repetition maximum (1RM) test and for the prediction of load-velocity (L-V) variables, as well as the ecological intra-day and inter-day reliability during free-wei...

Full description

Saved in:
Bibliographic Details
Main Authors: Boris Dragutinovic (Author), Mats Jacobs (Author), Joshua Feuerbacher (Author), Jan-Peter Goldmann (Author), Sulin Cheng (Author), Moritz Schumann (Author)
Format: Book
Published: Termedia Publishing House, 2023-05-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We investigated the ecological validity of an inertial measurement unit (IMU) (Vmaxpro) to assess the movement velocity (MV) during a 1-repetition maximum (1RM) test and for the prediction of load-velocity (L-V) variables, as well as the ecological intra-day and inter-day reliability during free-weight bench press (BP) and squat (SQ). Furthermore, we provide recommendations for the practical use of the sensor. Twenty-three strength-trained men completed an incremental 1RM test, whereas seventeen men further participated in another 3 sessions consisting of 3 repetitions with 4 different loads (30, 50, 70 and 90% of 1RM) to assess validity and intra- and inter‑day reliability, respectively. The MV was assessed using the Vmaxpro and a 3D motion capture system (MoCap). L-V variables and the 1RM were calculated based on submaximal velocities. The Vmaxpro showed high validity during the 1RM test for BP (r = 0.935) and SQ (r = 0.900), but with decreasing validity at lower MVs. The L-V variables and the 1RM demonstrated high validity for BP (r = 0.808-0.942) and SQ (r = 0.615-0.741) with a systematic overestimation. Coefficients of variance for intra- and inter-day reliability ranged from 2.4% to 9.7% and from 3.2% to 8.6% for BP and SQ, respectively. The Vmaxpro appears valid at high and moderately valid at low MVs. Depending on the required degree of accuracy, the sensor may be sufficient for the prediction of L-V variables and the 1RM. Our data indicate the sensor to be suitable for monitoring changes in MVs within and between training sessions.
Item Description:0860-021X
2083-1862
10.5114/biolsport.2024.125596