Liquid Biopsy of Bile based on Targeted Mass Spectrometry for the Diagnosis of Malignant Biliary Strictures

Bile holds biomarkers of malignant biliary strictures (MBS) but is unsuited for automated analyzers used in routine diagnostic laboratories. Selected reaction monitoring (SRM) is a flexible high‐throughput analytical approach based on targeted mass spectrometry (MS) already implemented in clinical s...

Full description

Saved in:
Bibliographic Details
Main Authors: Annie Adrait (Author), Jean‐Marc Dumonceau (Author), Myriam Delhaye (Author), Isabelle Annessi‐Ramseyer (Author), Jean‐Louis Frossard (Author), Yohann Couté (Author), Annarita Farina (Author)
Format: Book
Published: Wiley, 2021-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_764d34d6475f4ceca29cf5f74686b1f5
042 |a dc 
100 1 0 |a Annie Adrait  |e author 
700 1 0 |a Jean‐Marc Dumonceau  |e author 
700 1 0 |a Myriam Delhaye  |e author 
700 1 0 |a Isabelle Annessi‐Ramseyer  |e author 
700 1 0 |a Jean‐Louis Frossard  |e author 
700 1 0 |a Yohann Couté  |e author 
700 1 0 |a Annarita Farina  |e author 
245 0 0 |a Liquid Biopsy of Bile based on Targeted Mass Spectrometry for the Diagnosis of Malignant Biliary Strictures 
260 |b Wiley,   |c 2021-01-01T00:00:00Z. 
500 |a 1752-8062 
500 |a 1752-8054 
500 |a 10.1111/cts.12890 
520 |a Bile holds biomarkers of malignant biliary strictures (MBS) but is unsuited for automated analyzers used in routine diagnostic laboratories. Selected reaction monitoring (SRM) is a flexible high‐throughput analytical approach based on targeted mass spectrometry (MS) already implemented in clinical settings. We tested the hypothesis that SRM could be used to quantify cancer biomarkers in human bile. An SRM‐based assay was developed to simultaneously quantify up to 37 peptides from 13 bile proteins in a developmental cohort of 15 patients (MBS, n = 8; benign biliary stricture or obstruction (BBS), n = 7). The most reliable biomarkers were then absolutely quantified by SRM in a verification cohort of 67 patients (MBS, n = 37; BBS, n = 30). The diagnostic performances of single and combined biomarkers were assessed. In the developmental cohort, SRM‐based analysis revealed six protein biomarkers with significantly higher peptide ratios (endogenous vs. standard) in bile from MBS vs. BBS. In the verification cohort, five of these biomarkers proved good diagnostic ability (individual receiver operating characteristic‐area under the receiver operating characteristic curve (ROC‐AUC) up to 0.889, accuracies from 67.8% to 83.1%). Combining bile biomarkers and serum CA19‐9 in 2 panels allowed differentiating MBS from BBS with up to 0.929 ROC‐AUC and 89.8% accuracy. In this study, a newly developed SRM‐based assay proved able to simultaneously quantify multiple biomarkers in bile samples. The combination of bile biomarkers with serum CA19‐9 was highly accurate for the diagnosis of MBS. Liquid biopsy of bile based on targeted MS is eligible to support MBS diagnosis in clinical practice. 
546 |a EN 
690 |a Therapeutics. Pharmacology 
690 |a RM1-950 
690 |a Public aspects of medicine 
690 |a RA1-1270 
655 7 |a article  |2 local 
786 0 |n Clinical and Translational Science, Vol 14, Iss 1, Pp 148-152 (2021) 
787 0 |n https://doi.org/10.1111/cts.12890 
787 0 |n https://doaj.org/toc/1752-8054 
787 0 |n https://doaj.org/toc/1752-8062 
856 4 1 |u https://doaj.org/article/764d34d6475f4ceca29cf5f74686b1f5  |z Connect to this object online.