No Differences in Exercise Performance, Perceptual Response, or Safety Were Observed Among 3 Blood Flow Restriction Devices

Purpose: To compare 3 separate blood flow restriction (BFR) systems in their capacity to reduce repetitions to failure, impact perceptual responses, and cause adverse events during a low-load free-flow exercise. Methods: The study included healthy subjects aged 18 years or older who presented to an...

Full description

Saved in:
Bibliographic Details
Main Authors: Malik E. Dancy, M.D (Author), Andrew S. Alexander, M.D (Author), Muhammad J. Abbas, M.D (Author), Nicholas Rolnick, D.P.T (Author), Kareme D. Alder, M.D (Author), Yining Lu, M.D (Author), Kelechi R. Okoroha, M.D (Author)
Format: Book
Published: Elsevier, 2023-12-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_782b56c25f3c4d85bb25f66e9e935a5a
042 |a dc 
100 1 0 |a Malik E. Dancy, M.D.  |e author 
700 1 0 |a Andrew S. Alexander, M.D.  |e author 
700 1 0 |a Muhammad J. Abbas, M.D.  |e author 
700 1 0 |a Nicholas Rolnick, D.P.T.  |e author 
700 1 0 |a Kareme D. Alder, M.D.  |e author 
700 1 0 |a Yining Lu, M.D.  |e author 
700 1 0 |a Kelechi R. Okoroha, M.D.  |e author 
245 0 0 |a No Differences in Exercise Performance, Perceptual Response, or Safety Were Observed Among 3 Blood Flow Restriction Devices 
260 |b Elsevier,   |c 2023-12-01T00:00:00Z. 
500 |a 2666-061X 
500 |a 10.1016/j.asmr.2023.100822 
520 |a Purpose: To compare 3 separate blood flow restriction (BFR) systems in their capacity to reduce repetitions to failure, impact perceptual responses, and cause adverse events during a low-load free-flow exercise. Methods: The study included healthy subjects aged 18 years or older who presented to an ambulatory-care sports medicine clinic. On day 1, participants' demographic characteristics and anthropomorphic measurements were recorded. Each participant performed dumbbell biceps curl repetitions to failure using 20% of his or her 1-repetition maximum weight with each arm. Participants were exposed to 3 different tourniquet systems for familiarization. On day 2, each participant's arm was randomized to a cuff system, and the participant performed 2 sets of biceps curl repetitions to failure with the cuff inflated. Repetitions to failure, rating of perceived effort (RPE), rating of perceived discomfort, and pulse oxygenation levels were recorded after each set. On day 3, participants completed a survey of their perceived delayed-onset muscle soreness. Results: The final analysis was performed on 42 arms, with 14 limbs per system. The study population had a mean age of 28.7 ± 2.4 years and a mean body mass index of 24.9 ± 4.3. All 3 systems successfully reduced repetitions to failure compared with unrestricted low-load exercise from baseline to BFR set 1 and from baseline to BFR set 2. There were no significant between-group differences among BFR systems regarding the number of repetitions to failure performed at baseline versus BFR set 1 or BFR set 2. The Delfi Personalized Tourniquet System (PTS) cohort had the greatest reductions in repetitions to failure from BFR set 1 to BFR set 2 (P = .002) and reported the highest RPE after set 2 (P = .025). Conclusions: The Delfi PTS, SmartCuffs Pro, and BStrong BFR systems were each safe and were able to significantly reduce repetitions to failure compared with a low-load free-flow condition when used in a BFR exercise protocol. The Delfi PTS system may produce a higher RPE with prolonged use in comparison to the other systems. Level of Evidence: Level II, prospective cohort study. 
546 |a EN 
690 |a Sports medicine 
690 |a RC1200-1245 
655 7 |a article  |2 local 
786 0 |n Arthroscopy, Sports Medicine, and Rehabilitation, Vol 5, Iss 6, Pp 100822- (2023) 
787 0 |n http://www.sciencedirect.com/science/article/pii/S2666061X23001736 
787 0 |n https://doaj.org/toc/2666-061X 
856 4 1 |u https://doaj.org/article/782b56c25f3c4d85bb25f66e9e935a5a  |z Connect to this object online.