The mechanism of "killer turn" causing residual laxity after transtibial posterior cruciate ligament reconstruction

Background: The residual laxity after transtibial posterior cruciate ligament (PCL) reconstruction has been reported by several authors. The sharp angle where the graft exits the tibial tunnel, which is known as "killer turn", is believed to be the main reason. The purpose of this study wa...

Full description

Saved in:
Bibliographic Details
Main Authors: Yue Li (Author), Jin Zhang (Author), Guanyang Song (Author), Xu Li (Author), Hua Feng (Author)
Format: Book
Published: Elsevier, 2016-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_78aa2103db8d4ab19e8e1b58b0c5923b
042 |a dc 
100 1 0 |a Yue Li  |e author 
700 1 0 |a Jin Zhang  |e author 
700 1 0 |a Guanyang Song  |e author 
700 1 0 |a Xu Li  |e author 
700 1 0 |a Hua Feng  |e author 
245 0 0 |a The mechanism of "killer turn" causing residual laxity after transtibial posterior cruciate ligament reconstruction 
260 |b Elsevier,   |c 2016-01-01T00:00:00Z. 
500 |a 2214-6873 
500 |a 10.1016/j.asmart.2015.12.001 
520 |a Background: The residual laxity after transtibial posterior cruciate ligament (PCL) reconstruction has been reported by several authors. The sharp angle where the graft exits the tibial tunnel, which is known as "killer turn", is believed to be the main reason. The purpose of this study was to reveal the mechanism of "killer turn" and its effect on both graft and tunnel inlet. Methods: A total of 60 New Zealand white rabbits were included. All transtibial PCL reconstructions were performed in vitro using Achilles tendon autograft. The cyclic loading tests were conducted when reconstructed knees were subjected to 1500 cycles of tensile force of 50 N with the angle of pull at 45° to the tibial plateau. The tunnel inlet enlargement, graft elongation, stiffness, graft displacement, load to failure, and failure site were all recorded and analysed. Results: Fifty-eight New Zealand white rabbits were available for biomechanical evaluation. The subjects had significant graft elongation and tunnel enlargement. The graft displacement increased by a mean of 0.92±0.36 mm (16.70%). At the 1500th cycle, the grafts were significantly elongated by 5.59±4.98%, and the tunnel inlet diameter was also significantly enlarged by 12.08±4.31%. There was a linear correlation between total graft displacement and the two variables (R2=0.402, F=18.515, p<0.001). The coefficient for tunnel inlet enlargement was 0.419 (p=0.006), and for graft elongation was 0.583 (p=0.002). At the load-to-failure test, the failure load was 81.19±20.13 N. Of the 58 grafts, 31 (53.45%) failed at the "killer turn", 13 (22.41%) for the para-tunnel fracture, seven (12.07%) for the graft pull-out, and the remaining seven (12.07%) for the rupture at the mounting site. Conclusion: The mechanism of "killer turn" compromising posterior stability was that the repetitive friction between graft and tunnel inlet not only attenuated the graft, but also enlarged the tunnel inlet, leading to the displacement of the graft. 
546 |a EN 
690 |a biomechanical 
690 |a osteoporosis 
690 |a posterior cruciate ligament 
690 |a Sports medicine 
690 |a RC1200-1245 
655 7 |a article  |2 local 
786 0 |n Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology, Vol 3, Iss C, Pp 13-18 (2016) 
787 0 |n http://www.sciencedirect.com/science/article/pii/S2214687315000527 
787 0 |n https://doaj.org/toc/2214-6873 
856 4 1 |u https://doaj.org/article/78aa2103db8d4ab19e8e1b58b0c5923b  |z Connect to this object online.