Zirconia crowns cemented on titanium bars using CAD/CAM: a five-year follow-up prospective clinical study of 9 patients

Abstract Background The purpose of this prospective clinical study was to evaluate clinical results of the passive fit of the substructure in the Toronto bridge and the chipping or delamination of the ceramic veneering on the zirconia-support, after 5 years, in nine patients rehabilitated with zirco...

Full description

Saved in:
Bibliographic Details
Main Authors: Antonio Scarano (Author), Marco Stoppaccioli (Author), Tommaso Casolino (Author)
Format: Book
Published: BMC, 2019-12-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_7a59ab5eb0f044f4b1843efc72b8cee6
042 |a dc 
100 1 0 |a Antonio Scarano  |e author 
700 1 0 |a Marco Stoppaccioli  |e author 
700 1 0 |a Tommaso Casolino  |e author 
245 0 0 |a Zirconia crowns cemented on titanium bars using CAD/CAM: a five-year follow-up prospective clinical study of 9 patients 
260 |b BMC,   |c 2019-12-01T00:00:00Z. 
500 |a 10.1186/s12903-019-0988-x 
500 |a 1472-6831 
520 |a Abstract Background The purpose of this prospective clinical study was to evaluate clinical results of the passive fit of the substructure in the Toronto bridge and the chipping or delamination of the ceramic veneering on the zirconia-support, after 5 years, in nine patients rehabilitated with zirconia crowns cemented on titanium bars using CAD/CAM technology. Methods A total of nine healthy patient fully edentulous in the upper and lower jaws with non-contributory past medical anamnesis needing full fixed total prosthesis maxilla and mandible were included in this clinical study, where a total 9 mandibles and 9 jaws were treated. The inclusion criteria in order for a patient to participate in the study were: a signed consent form, fully edentulous in the upper and lower jaws, required a full fixed total prosthesis restoration. The exclusion criteria were age limitation of less than 18 years old, chemotherapy, head and neck radiation therapy, diabetes or periodontal disease, smoking and severe illness. All patients received zirconia crowns cemented on titanium bars using CAD/CAM technology. The primary outcome of this study was to examine the survival rate of the zirconia crowns cemented on titanium bars using CAD/CAM technology during the observation period. Any chipping or delamination of the zirconia crowns of the restorations was considered as failure. The secondary outcome was to evaluate the passive fit of the substructure on the implants, loose of occlusal screws, implant survival and satisfactory occlusion. Results In 5 years of follow-up no evidence of chipping or delamination of the ceramic veneering on the zirconia crown supported were observed. Fifteen finished protesis (93.75%) showed satisfactory occlusion and only one case (6.25%) required significant occlusal adjustment. During the first year recall all bars were stable (100%) no mobility of protheses was recorded. After 5 years all bars were stable (100%) and no mobility of protheses was recorded. Conclusion The computerized workflow for the process of building bar and prosthesis ensures reproducible results and excellent adaptation and passive insertion of them, as well as conditions for avoiding mechanical complications and guarantees stability of screw-implant abutments. 
546 |a EN 
690 |a CAD/CAM 
690 |a Zirconia 
690 |a Dental implants 
690 |a Digital workflow 
690 |a Toronto bridge 
690 |a Computerized workflow 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n BMC Oral Health, Vol 19, Iss 1, Pp 1-9 (2019) 
787 0 |n https://doi.org/10.1186/s12903-019-0988-x 
787 0 |n https://doaj.org/toc/1472-6831 
856 4 1 |u https://doaj.org/article/7a59ab5eb0f044f4b1843efc72b8cee6  |z Connect to this object online.