A novel animal model for residence time evaluation of injectable hyaluronic acid-based fillers using high-frequency ultrasound-based approach

Filomena Merola,1 Mario Scrima,1 Carmela Melito,1 Antonio Iorio,1 Claudio Pisano,2 Andrea Maria Giori,3 Angela Ferravante1 1Research and Development, Bouty SpA, Ariano Irpino, Italy; 2Medicinal Investigational Research, Biogem, Ariano Irpino, Italy; 3Research and Development, IBSA Farmaceutici Itali...

Full description

Saved in:
Bibliographic Details
Main Authors: Merola F (Author), Scrima M (Author), Melito C (Author), Iorio A (Author), Pisano C (Author), Giori AM (Author), Ferravante A (Author)
Format: Book
Published: Dove Medical Press, 2018-07-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Filomena Merola,1 Mario Scrima,1 Carmela Melito,1 Antonio Iorio,1 Claudio Pisano,2 Andrea Maria Giori,3 Angela Ferravante1 1Research and Development, Bouty SpA, Ariano Irpino, Italy; 2Medicinal Investigational Research, Biogem, Ariano Irpino, Italy; 3Research and Development, IBSA Farmaceutici Italia, Lodi, Italy Background: Hyaluronic acid (HA)-based devices are among the most popular filler agents for skin rejuvenation. One of the principal goals is the improvement in residence time of HA-based products, to increase their performance and reduce frequency of the treatment. So, understanding fillers, behavior after subcutaneous injection is a fundamental aspect for discovery and optimization of new products. Current in vivo approaches to detect/quantify injected HA fillers are not always well optimized or easy to apply. Objective: To develop more efficacious and noninvasive diagnostic tools to make a quantitative evaluation of the degradation of fillers in a small animal model. Materials and methods: We evaluated the residence time of different HA-based fillers, fluorescein-labeled and not, injected subcutaneously in mice. Volumes of fillers were monitored through high-frequency ultrasound (HF-US) method while fluorescence intensity through the well-established fluorescence living imaging method. To confirm the effectiveness of HF-US, obtained volumetric measurements were compared with fluorescence intensity values. Results: Both the presented methods revealed the same degradation kinetics for the tested products. Conclusion: The two used methods are fully comparable and quantitatively accurate. The presented approach has been proved to be noninvasive, sensitive, and reproducible. Keywords: hyaluronic acid, hyaluronan, dermal filler, HF-US, ultrasound, animal model
Item Description:1178-7015