Post-mortem magnetic resonance microscopy (MRM) of the murine brain at 7 Tesla results in a gain of resolution as compared to in-vivo MRM

Small animal MRI with high field strength allows imaging of the living animal. However, spatial resolution in in-vivo brain imaging is limited by the scanning time. Measurements of fixated mouse brains allow longer measurement time, but fixation procedures are time consuming, since the process of fi...

Full description

Saved in:
Bibliographic Details
Main Authors: Oliver evon Bohlen und Halbach (Author), Martin eLotze (Author), Jörg Peter Pfannmöller (Author)
Format: Book
Published: Frontiers Media S.A., 2014-06-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_7c519f7dcc20462798d81bd42a9ca553
042 |a dc 
100 1 0 |a Oliver evon Bohlen und Halbach  |e author 
700 1 0 |a Martin eLotze  |e author 
700 1 0 |a Jörg Peter Pfannmöller  |e author 
245 0 0 |a Post-mortem magnetic resonance microscopy (MRM) of the murine brain at 7 Tesla results in a gain of resolution as compared to in-vivo MRM 
260 |b Frontiers Media S.A.,   |c 2014-06-01T00:00:00Z. 
500 |a 1662-5129 
500 |a 10.3389/fnana.2014.00047 
520 |a Small animal MRI with high field strength allows imaging of the living animal. However, spatial resolution in in-vivo brain imaging is limited by the scanning time. Measurements of fixated mouse brains allow longer measurement time, but fixation procedures are time consuming, since the process of fixation may take several weeks. We here present a quick and simple post-mortem approach without fixation that allows high-resolution MRI even at 7 Tesla (T2-weighted MRI). This method was compared to in-vivo scans with optimized spatial resolution for the investigation of anaesthetized mice (T1-weighted MRI) as well as to ex-situ scans of fixed brains (T1- and T2-weighted scans) by using standard MRI-sequences, along with anatomic descriptions of areas observable in the MRI, analysis of tissue shrinkage and post-processing procedures (intensity inhomogeneity correction, PCNN3D brain extract, SPMMouse segmentation and volumetric measurement). Post-mortem imaging quality was sufficient to determine small brain substructures on the morphological level, provided fast possibilities for volumetric acquisition and for automatized processing without manual correction. Moreover, since no fixation was used, tissue shrinkage due to fixation does not occur as it is, e.g., the case by using ex-vivo brains that have been kept in fixatives for several days. Thus, the introduced method is well-suited for comparative investigations, since it allows determining small structural alterations in the murine brain at a reasonable high resolution even by MRI performed at 7 Tesla. 
546 |a EN 
690 |a in-vivo 
690 |a segmentation 
690 |a signal to noise ratio 
690 |a spatial resolution 
690 |a MRI imaging 
690 |a post-mortem 
690 |a Neurosciences. Biological psychiatry. Neuropsychiatry 
690 |a RC321-571 
690 |a Human anatomy 
690 |a QM1-695 
655 7 |a article  |2 local 
786 0 |n Frontiers in Neuroanatomy, Vol 8 (2014) 
787 0 |n http://journal.frontiersin.org/Journal/10.3389/fnana.2014.00047/full 
787 0 |n https://doaj.org/toc/1662-5129 
856 4 1 |u https://doaj.org/article/7c519f7dcc20462798d81bd42a9ca553  |z Connect to this object online.