Ultrasonic evaluation of influence of hard acrylic resin denture on blood flow of mandibular denture supporting mucosa utilizing duplex color Doppler studies: An in vivo study

Aims: To determine the influence of hard acrylic denture base materials on the blood flow of mandibular denture supporting mucosa over a period of six months time. Materials and Methods: Select fifteen edentulous patients of age 55-75 years. The blood flow of the mandibular denture supporting mucosa...

Full description

Saved in:
Bibliographic Details
Main Authors: S Binsu (Author), K Chandrasekharan Nair (Author), Bijoy Jhon (Author), Sanjna Nayar (Author), Jose Julian (Author), Muhammed Shahid (Author)
Format: Book
Published: Wolters Kluwer Medknow Publications, 2017-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_7d3435d0def14f7a8ee75a28da5a2ba4
042 |a dc 
100 1 0 |a S Binsu  |e author 
700 1 0 |a K Chandrasekharan Nair  |e author 
700 1 0 |a Bijoy Jhon  |e author 
700 1 0 |a Sanjna Nayar  |e author 
700 1 0 |a Jose Julian  |e author 
700 1 0 |a Muhammed Shahid  |e author 
245 0 0 |a Ultrasonic evaluation of influence of hard acrylic resin denture on blood flow of mandibular denture supporting mucosa utilizing duplex color Doppler studies: An in vivo study 
260 |b Wolters Kluwer Medknow Publications,   |c 2017-01-01T00:00:00Z. 
500 |a 0972-4052 
500 |a 1998-4057 
500 |a 10.4103/jips.jips_12_17 
520 |a Aims: To determine the influence of hard acrylic denture base materials on the blood flow of mandibular denture supporting mucosa over a period of six months time. Materials and Methods: Select fifteen edentulous patients of age 55-75 years. The blood flow of the mandibular denture supporting mucosa was measured bilaterally in the molar region and in the incisor region utilizing Ultrasound colour Doppler (2D and Duplex Imaging). Measurements were performed prior to denture insertion and later after the dentures were worn for 1 month, 2 months, 3 months, 4 months, 5 months and 6 months. Statistical analysis used: Mean blood flow as measured by Ultrasound colour Doppler were tabulated significant changes if any at various time interval in comparison to baseline was assessed by Kruskalwallis ANOVA test followed by Wilkoxan sign rank test for pairwise comparison.( In the present study, P < 0.05 was considered as the level of significance). Results: The denture supporting mucosa exhibited a progressive reduction in the blood flow both with hard denture. The blood flow change with hard denture was a reversible condition as the blood flow improved at the end of six months. Kruskalwallis ANOVA test revealed no significant change in the blood flow at any interval of time in comparison to base value (P = 0.133). Conclusions: Within the limitations of the study denture supporting mucosa exhibited a progressive reduction in the blood flow with hard denture which was reversible. 
546 |a EN 
690 |a Denture 
690 |a ultrasonography 
690 |a vascularity 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n The Journal of Indian Prosthodontic Society, Vol 17, Iss 3, Pp 289-294 (2017) 
787 0 |n http://www.j-ips.org/article.asp?issn=0972-4052;year=2017;volume=17;issue=3;spage=289;epage=294;aulast=Binsu 
787 0 |n https://doaj.org/toc/0972-4052 
787 0 |n https://doaj.org/toc/1998-4057 
856 4 1 |u https://doaj.org/article/7d3435d0def14f7a8ee75a28da5a2ba4  |z Connect to this object online.