Determination of Diphenylamine in Gunshot Residue by HPLC-MS/MS

A high performance liquid chromatography tandem mass spectrometry/mass spectrometry (HPLC-MS/MS) protocol was developed for the determination of diphenylamine (DPA). Four productions of DPA were selected for qualitative assay and the peak area of the main product ion for quantitation. By means of se...

Full beskrivning

Sparad:
Bibliografiska uppgifter
Huvudupphovsmän: Hongcheng Mei (Författare, medförfattare), Yangke Quan (Författare, medförfattare), Wenhao Wang (Författare, medförfattare), Hong Zhou (Författare, medförfattare), Zhanfang Liu (Författare, medförfattare), Huixia Shi (Författare, medförfattare), Peng Wang (Författare, medförfattare)
Materialtyp: Bok
Publicerad: Wolters Kluwer Medknow Publications, 2016-01-01T00:00:00Z.
Ämnen:
Länkar:Connect to this object online.
Taggar: Lägg till en tagg
Inga taggar, Lägg till första taggen!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_7f59f99a18f0496ab2eea6c6dbf06f5f
042 |a dc 
100 1 0 |a Hongcheng Mei  |e author 
700 1 0 |a Yangke Quan  |e author 
700 1 0 |a Wenhao Wang  |e author 
700 1 0 |a Hong Zhou  |e author 
700 1 0 |a Zhanfang Liu  |e author 
700 1 0 |a Huixia Shi  |e author 
700 1 0 |a Peng Wang  |e author 
245 0 0 |a Determination of Diphenylamine in Gunshot Residue by HPLC-MS/MS 
260 |b Wolters Kluwer Medknow Publications,   |c 2016-01-01T00:00:00Z. 
500 |a 2349-5014 
500 |a 10.4103/2349-5014.162808 
520 |a A high performance liquid chromatography tandem mass spectrometry/mass spectrometry (HPLC-MS/MS) protocol was developed for the determination of diphenylamine (DPA). Four productions of DPA were selected for qualitative assay and the peak area of the main product ion for quantitation. By means of separation using an Agilent Extend-C18 column (CA, USA) (150 mm × 4.6 mm, 5 μm) with methanol-water (90:10) as the mobile phase, DPA was detected by electrospray ionization (ESI) tandem mass spectrometry in positive mode. The linearity of the peak area versus concentration ranged 5-500 ng/mL, r 2 = 0.9978. The limit of detection (S/N =3) of this method was 0.3 ng/mL. This method is applicable for the determination of DPA in gunshot residue. 
546 |a EN 
690 |a Diphenylamine 
690 |a gunshot residue 
690 |a high performance liquid chromatography-mass spectrometry/mass spectrometry 
690 |a Public aspects of medicine 
690 |a RA1-1270 
655 7 |a article  |2 local 
786 0 |n Journal of Forensic Science and Medicine, Vol 2, Iss 1, Pp 18-21 (2016) 
787 0 |n http://www.jfsmonline.com/article.asp?issn=2349-5014;year=2016;volume=2;issue=1;spage=18;epage=21;aulast=Mei 
787 0 |n https://doaj.org/toc/2349-5014 
856 4 1 |u https://doaj.org/article/7f59f99a18f0496ab2eea6c6dbf06f5f  |z Connect to this object online.