<b>Biophotogrammetry: reliability of measurements obtained with a posture assessment software (SAPO)</b>. DOI: 10.5007/1980-0037.2011v13n4p299

Photogrammetry is a valuable tool for the diagnosis and measurement of postural changes, but the lack of standardization of anatomical references and angular measures impairs the comparison between studies and compromises the reliability of the results. The objective of this study was to evaluate th...

Full description

Saved in:
Bibliographic Details
Main Authors: Juliana Alves Souza (Author), Fernanda Pasinato (Author), Débora Basso (Author), Eliane Castilhos Rodrigues Corrêa (Author), Ana Maria Toniolo da Silva (Author)
Format: Book
Published: Universidade Federal de Santa Catarina, 2011-08-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_814b06a986e94ba6b0e6bcfd1af2d215
042 |a dc 
100 1 0 |a Juliana Alves Souza  |e author 
700 1 0 |a Fernanda Pasinato  |e author 
700 1 0 |a Débora Basso  |e author 
700 1 0 |a Eliane Castilhos Rodrigues Corrêa  |e author 
700 1 0 |a Ana Maria Toniolo da Silva  |e author 
245 0 0 |a <b>Biophotogrammetry: reliability of measurements obtained with a posture assessment software (SAPO)</b>. DOI: 10.5007/1980-0037.2011v13n4p299 
260 |b Universidade Federal de Santa Catarina,   |c 2011-08-01T00:00:00Z. 
500 |a 1415-8426 
500 |a 1980-0037 
520 |a Photogrammetry is a valuable tool for the diagnosis and measurement of postural changes, but the lack of standardization of anatomical references and angular measures impairs the comparison between studies and compromises the reliability of the results. The objective of this study was to evaluate the inter- and intraexaminer reliability of angular measures proposed by the SAPO posture assessment software (v. 0.68). Twenty-four subjects were photographed in the standing position according to the recommendations of the SAPO software. Three examiners (A, B and C) experienced in the use of the software analyzed the images and repeated the analysis after 7 days. Variance, intraclass correlation coefficient (ICC), and t-test adopting a level of significance of 5% were applied. With respect to interexaminer reliability among the 20 angles measured, two were classified as unacceptable (A13: ICC = 0.623; A14: ICC = 0.568), one as acceptable (A19: ICC = 0.743), one as very good (A20: ICC = 0.860), and 16 as excellent (ICC ≥ 0.90). Evaluation of repeatability of the method by the same examiner showed that two angles measured by examiner A differed significantly between the two measurements (A11: p = 0.015; A12: p = 0.026), as did two angles measured by examiner B (A2: p = 0.019; A12: p = 0.015) and one angle measured by examiner C (A16, p = 0.011). In conclusion, comparison between different examiners showed that the angles proposed by the SAPO protocol are reliable for the measurement of body segments. 
546 |a EN 
546 |a PT 
690 |a Evaluation of research programs and tool 
690 |a Photogrammetry 
690 |a Posture 
690 |a Reproducibility. 
690 |a Sports 
690 |a GV557-1198.995 
690 |a Medicine (General) 
690 |a R5-920 
655 7 |a article  |2 local 
786 0 |n Revista Brasileira de Cineantropometria e Desempenho Humano, Vol 13, Iss 4, Pp 299-305 (2011) 
787 0 |n http://www.periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2011v13n4p299/17905 
787 0 |n https://doaj.org/toc/1415-8426 
787 0 |n https://doaj.org/toc/1980-0037 
856 4 1 |u https://doaj.org/article/814b06a986e94ba6b0e6bcfd1af2d215  |z Connect to this object online.