Radiopacity evaluation of root-end filling materials by digitization of images

The purpose of this study was to evaluate the radiopacity of 5 root-end filling materials (white MTA-Angelus, grey MTA-Angelus, IRM, Super EBA and Sealer 26). Five specimens (10 mm diameter X 1 mm thickness) were made from each material and radiographed next to an aluminum stepwedge varying in thick...

Full description

Saved in:
Bibliographic Details
Main Authors: Mario Tanomaru-Filho (Author), Guilherme Ferreira da Silva (Author), Marco Antonio Húngaro Duarte (Author), Marcelo Gonçalves (Author), Juliane Maria Guerreiro Tanomaru (Author)
Format: Book
Published: University of São Paulo, 2008-12-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_834c5853a8f34e0189ca7f47e08c3738
042 |a dc 
100 1 0 |a Mario Tanomaru-Filho  |e author 
700 1 0 |a Guilherme Ferreira da Silva  |e author 
700 1 0 |a Marco Antonio Húngaro Duarte  |e author 
700 1 0 |a Marcelo Gonçalves  |e author 
700 1 0 |a Juliane Maria Guerreiro Tanomaru  |e author 
245 0 0 |a Radiopacity evaluation of root-end filling materials by digitization of images 
260 |b University of São Paulo,   |c 2008-12-01T00:00:00Z. 
500 |a 10.1590/S1678-77572008000600004 
500 |a 1678-7757 
500 |a 1678-7765 
520 |a The purpose of this study was to evaluate the radiopacity of 5 root-end filling materials (white MTA-Angelus, grey MTA-Angelus, IRM, Super EBA and Sealer 26). Five specimens (10 mm diameter X 1 mm thickness) were made from each material and radiographed next to an aluminum stepwedge varying in thickness from 2 to 16 mm. Radiographs were digitized and the radiopacity of the materials was compared to that of the aluminum stepwedge using VIXWIN 2000 software in millimeters of aluminum (mm Al). Data were analyzed statistically by ANOVA and Tukey's test at 5% significance level. Radiopacity values varied from 3 mm Al to 5.9 mm Al. Sealer 26 and IRM presented the highest radiopacity values (p<0.05), while white/grey MTA and Super EBA presented the lowest radiopacity values (p<0.05). The tested root-end filling materials presented different radiopacities, white/grey MTA and Super EBA being the least radiopaque materials. 
546 |a EN 
690 |a Radiopacity 
690 |a Retrograde obturation 
690 |a Root canal filling materials 
690 |a Radiology 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Journal of Applied Oral Science, Vol 16, Iss 6, Pp 376-379 (2008) 
787 0 |n http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572008000600004 
787 0 |n https://doaj.org/toc/1678-7757 
787 0 |n https://doaj.org/toc/1678-7765 
856 4 1 |u https://doaj.org/article/834c5853a8f34e0189ca7f47e08c3738  |z Connect to this object online.