Effect of Aging of Orthodontic Aligners in Different Storage Media on Force and Torque Generation: An In Vitro Study

The aim of this study is to study the effect of aging in different media (deionized water and artificial saliva) on the force/torque generation by thermoplastic orthodontic aligners. Ten thermoformed aligners, made of Essix ACE<sup>®</sup> thermoplastic sheets, were aged in deionized wat...

Full description

Saved in:
Bibliographic Details
Main Authors: Tarek M. Elshazly (Author), Diva Nang (Author), Bijan Golkhani (Author), Hanaa Elattar (Author), Christoph Bourauel (Author)
Format: Book
Published: MDPI AG, 2023-02-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_865f701d23a74c02b81cc7f01e714e47
042 |a dc 
100 1 0 |a Tarek M. Elshazly  |e author 
700 1 0 |a Diva Nang  |e author 
700 1 0 |a Bijan Golkhani  |e author 
700 1 0 |a Hanaa Elattar  |e author 
700 1 0 |a Christoph Bourauel  |e author 
245 0 0 |a Effect of Aging of Orthodontic Aligners in Different Storage Media on Force and Torque Generation: An In Vitro Study 
260 |b MDPI AG,   |c 2023-02-01T00:00:00Z. 
500 |a 10.3390/oral3010007 
500 |a 2673-6373 
520 |a The aim of this study is to study the effect of aging in different media (deionized water and artificial saliva) on the force/torque generation by thermoplastic orthodontic aligners. Ten thermoformed aligners, made of Essix ACE<sup>®</sup> thermoplastic sheets, were aged in deionized water and in artificial saliva over two weeks at 37 °C, five in each medium. The force/torque generated on upper second premolar (Tooth 25) of a resin model was measured at day 0 (before aging), 2, 4, 6, 10, and 14, using a biomechanical test set-up. The results showed that aging of aligners by storage in aging agent has no significant impact on their force/torque decay. No significant differences were also found in force/torque between the aligners stored in deionized water nor artificial saliva. The vertical extrusion-intrusion forces were measured in the range of 1.4 to 4.6 N, the horizontal oro-vestibular forces were 1.3 to 2.5 N, while the torques on mesio-distal rotation were 5.4 to 41.7 Nmm. It could be concluded that the influence of saliva only on the mechanical properties can be classified as insignificant, and no significant difference between artificial aging in deionized water or artificial saliva was observed. 
546 |a EN 
690 |a biomechanics 
690 |a orthodontic force 
690 |a torque 
690 |a tooth movement 
690 |a removable thermoplastic appliance 
690 |a aging 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Oral, Vol 3, Iss 1, Pp 67-76 (2023) 
787 0 |n https://www.mdpi.com/2673-6373/3/1/7 
787 0 |n https://doaj.org/toc/2673-6373 
856 4 1 |u https://doaj.org/article/865f701d23a74c02b81cc7f01e714e47  |z Connect to this object online.