Appropriate electrode placement site of electric pulp tester for the premolars: A clinical study

Context: Electric pulp testers (EPTs) are widely used as diagnostic aid in dentistry for dental pulp. This delivers enough current to overcome enamel and dentin resistance and to stimulate the myelinated sensory fibers at the junction of pulp and dentin. Such testing requires the electrode to be in c...

Full description

Saved in:
Bibliographic Details
Main Authors: Seema Dinesh Bargale (Author), Shital Kiran Davangere Padmanabh (Author)
Format: Book
Published: Wolters Kluwer Medknow Publications, 2015-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_873e438adb5945d79f624846d82e85a4
042 |a dc 
100 1 0 |a Seema Dinesh Bargale  |e author 
700 1 0 |a Shital Kiran Davangere Padmanabh  |e author 
245 0 0 |a Appropriate electrode placement site of electric pulp tester for the premolars: A clinical study 
260 |b Wolters Kluwer Medknow Publications,   |c 2015-01-01T00:00:00Z. 
500 |a 0970-4388 
500 |a 1998-3905 
500 |a 10.4103/0970-4388.155128 
520 |a Context: Electric pulp testers (EPTs) are widely used as diagnostic aid in dentistry for dental pulp. This delivers enough current to overcome enamel and dentin resistance and to stimulate the myelinated sensory fibers at the junction of pulp and dentin. Such testing requires the electrode to be in contact with the surface of the tooth, with optimal positions identified for anterior teeth, premolars, and molars. Aims: To determine the best site position of EPT on premolars. The objective of electric pulp testing was to determine the sensibility of each premolar at the lowest sensory response threshold. Settings and Design: Clinical study Materials and Methods: The premolars of 20 patients between 13 and 15 years accompanied with parents, free of restorations, and caries were selected. Five sites on the crown were tested with EPT for minimum of four times. Statistical analysis used: One-way analysis of variance test and the Tukey's honestly significant difference test. Results: The lowest threshold response was noted at the incisal edge of the tooth; the middle third had a higher threshold among all the different placement of electrode. Statistically significant difference was observed for occlusal surface in terms of region of placement of electrode. Conclusions: This experiment found the best electrode site for pulp testing in premolars. The appropriate EPT site was on the occlusal surface of maxillary and mandibular premolars. 
546 |a EN 
690 |a Dental pulp innervations 
690 |a electrodiagnosis 
690 |a pulp vitality test  
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Journal of Indian Society of Pedodontics and Preventive Dentistry, Vol 33, Iss 2, Pp 138-142 (2015) 
787 0 |n http://www.jisppd.com/article.asp?issn=0970-4388;year=2015;volume=33;issue=2;spage=138;epage=142;aulast=Bargale 
787 0 |n https://doaj.org/toc/0970-4388 
787 0 |n https://doaj.org/toc/1998-3905 
856 4 1 |u https://doaj.org/article/873e438adb5945d79f624846d82e85a4  |z Connect to this object online.