Effect of sonic and ultrasonic activation on physicochemical properties of root canal sealers

Abstract Objective: To evaluate the effect of ultrasonic and sonic activation on physicochemical properties of AH Plus, MTA Fillapex, ADSeal, GuttaFlow Bioseal, and GuttaFlow 2 sealers. Methodology: Three experimental groups were formed: no activation (NA), ultrasonic activation (UA), and sonic acti...

Full description

Saved in:
Bibliographic Details
Main Authors: Fabiane Carneiro Lopes (Author), Caio Zangirolami (Author), Jardel Francisco Mazzi-Chaves (Author), Alice Corrêa Silva-Sousa (Author), Bruno Monguilhott Crozeta (Author), Yara Teresinha Corrêa Silva-Sousa (Author), Manoel Damião Sousa-Neto (Author)
Format: Book
Published: University of São Paulo.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_8970a6f49209465b9c7d75051b0b768d
042 |a dc 
100 1 0 |a Fabiane Carneiro Lopes  |e author 
700 1 0 |a Caio Zangirolami  |e author 
700 1 0 |a Jardel Francisco Mazzi-Chaves  |e author 
700 1 0 |a Alice Corrêa Silva-Sousa  |e author 
700 1 0 |a Bruno Monguilhott Crozeta  |e author 
700 1 0 |a Yara Teresinha Corrêa Silva-Sousa  |e author 
700 1 0 |a Manoel Damião Sousa-Neto  |e author 
245 0 0 |a Effect of sonic and ultrasonic activation on physicochemical properties of root canal sealers 
260 |b University of São Paulo. 
500 |a 1678-7765 
500 |a 10.1590/1678-7757-2018-0556 
520 |a Abstract Objective: To evaluate the effect of ultrasonic and sonic activation on physicochemical properties of AH Plus, MTA Fillapex, ADSeal, GuttaFlow Bioseal, and GuttaFlow 2 sealers. Methodology: Three experimental groups were formed: no activation (NA), ultrasonic activation (UA), and sonic activation (SA). The sealers were manipulated according to the manufacturers' instructions. A 3-mL syringe was adapted to receive 1 mL of sealer. Activation was performed with a 20/.01 ultrasonic insert (20 s/1W) in the UA group. A size 35.04 sonic tip was used (20 s/10,000 cycles/min-1) in the SA group. The molds for physicochemical analysis were filled and evaluated according to ANSI/ADA specification no. 57: setting time (ST), flow (FL), dimensional change (DC), solubility (SB), and radiopacity (RD). Statistical analysis was performed by Kruskal-Wallis, one-way ANOVA, and Tukey's tests (P<0.05). Results: Regarding ST, only AH Plus and GuttaFlow 2 in the NA group met the ANSI/ADA standards. All FL values were greater than 20 mm in diameter, as determined by ANSI/ADA. The tested sealers and protocols did not comply with the ANSI/ADA standards for DC. As for SB, only MTA Fillapex, regardless of the activation protocol, did not follow the ANSI/ADA standards. All of the investigated sealers, regardless of the activation protocol, presented radiographic density higher than 3 mm Al, as proposed by ANSI/ADA. Conclusions: UA and SA promoted changes in the physicochemical properties of the evaluated root canal sealers, mainly in ST and F. Thus, it is important to evaluate the physicochemical properties of endodontic sealers associated with activation techniques prior to clinical application in order to determine whether the properties follow the parameters set by ANSI/ADA, ensuring safety and quality of root canal filling. 
546 |a EN 
690 |a Root canal filling materials 
690 |a Physicochemical analysis 
690 |a Ultrasonics 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Journal of Applied Oral Science, Vol 27 
787 0 |n http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572019000100474&lng=en&tlng=en 
787 0 |n https://doaj.org/toc/1678-7765 
856 4 1 |u https://doaj.org/article/8970a6f49209465b9c7d75051b0b768d  |z Connect to this object online.