Influence of the distance of the curing light source and composite shade on hardness of two composites

This study evaluated the influence of curing tip distance, shade and filler particle size on Vickers microhardness (VHN) of composite resins. Two composites were tested: Filtek Z250 microhybrid (3M ESPE; shades A1 and A3.5) and Filtek Supreme nanofilled (3M ESPE; shades A1B and A3.5B). For each resi...

Full description

Saved in:
Bibliographic Details
Main Authors: Thaís Thomé (Author), Washington Steagall Jr (Author), Arlene Tachibana (Author), Sheila Regina Maia Braga (Author), Miriam Lacalle Turbino (Author)
Format: Book
Published: University of São Paulo, 2007-12-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_8bfae47110b140c5a1e99a5d722f6fb1
042 |a dc 
100 1 0 |a Thaís Thomé  |e author 
700 1 0 |a Washington Steagall Jr.  |e author 
700 1 0 |a Arlene Tachibana  |e author 
700 1 0 |a Sheila Regina Maia Braga  |e author 
700 1 0 |a Miriam Lacalle Turbino  |e author 
245 0 0 |a Influence of the distance of the curing light source and composite shade on hardness of two composites 
260 |b University of São Paulo,   |c 2007-12-01T00:00:00Z. 
500 |a 10.1590/S1678-77572007000600006 
500 |a 1678-7757 
500 |a 1678-7765 
520 |a This study evaluated the influence of curing tip distance, shade and filler particle size on Vickers microhardness (VHN) of composite resins. Two composites were tested: Filtek Z250 microhybrid (3M ESPE; shades A1 and A3.5) and Filtek Supreme nanofilled (3M ESPE; shades A1B and A3.5B). For each resin, 42 specimens (5 mm in diameter and 2 mm height) were prepared being 21 for each shade. The specimens were exposed using a 20-second exposure to a quartz-tungsten-halogen light source with an irradiance of approximately 560 mW/cm², at the following distances: 0 mm (surface contact), 6 mm and 12 mm from composite surface. Effectiveness of cure of different resins, shades and curing distances was determined by measuring the top and bottom hardness (VHN) of specimens using a digital microhardness tester (load: 50 g; dwell time: 45 seconds) 24 hours following curing. The hardness ratio was calculated by dividing VHN of the bottom surface by VHN of top surface. Three-way ANOVA and Tukey's post-hoc test (p<0.05) revealed statistically significant differences for all analyzed factors. As for top hardness, as microhardness ratio (bottom/top), the factors shade, distance and composite filler particle size exerted influence on resin curing. Lighter shade composites (A1 and A1B) showed higher hardness values. At 6 and 12 mm curing tip distances, hardness was lower when compared to 0 mm. The microhybrid composite resin presented higheer hardness, being its microhardness ratio satisfactory only at 0 mm for both shades and at 6 mm for the lighter shade. The nanofilled composite resin did not present satisfactory microhardness at the bottom while the microhybrid composite resin had higher hardness than the nanofilled. Composite's curing tip distance and shade can influence hardness. 
546 |a EN 
690 |a Hardness tests 
690 |a Composite resins 
690 |a Shades 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Journal of Applied Oral Science, Vol 15, Iss 6, Pp 486-491 (2007) 
787 0 |n http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572007000600006 
787 0 |n https://doaj.org/toc/1678-7757 
787 0 |n https://doaj.org/toc/1678-7765 
856 4 1 |u https://doaj.org/article/8bfae47110b140c5a1e99a5d722f6fb1  |z Connect to this object online.