Evaluation of stress distribution characteristics on various bar designs of three-implant-supported mandibular overdentures

Objective: Implant-supported-overdentures, instead of conventional complete dentures, are frequently recommended to rehabilitate patients having edentulous mandible. The aim of this study was to evaluate the stress distribution characteristics of mandibular implant-supported overdentures with four d...

Full description

Saved in:
Bibliographic Details
Main Authors: Emre Tokar (Author), Serdar Polat (Author), Bülent Uludağ (Author)
Format: Book
Published: Gazi University, 2017-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_8c91844fb093485f94b4d6b7c3d6ad30
042 |a dc 
100 1 0 |a Emre Tokar  |e author 
700 1 0 |a Serdar Polat  |e author 
700 1 0 |a Bülent Uludağ  |e author 
245 0 0 |a Evaluation of stress distribution characteristics on various bar designs of three-implant-supported mandibular overdentures 
260 |b Gazi University,   |c 2017-01-01T00:00:00Z. 
500 |a 10.17214/gaziaot.273903 
500 |a 2147-690X 
520 |a Objective: Implant-supported-overdentures, instead of conventional complete dentures, are frequently recommended to rehabilitate patients having edentulous mandible. The aim of this study was to evaluate the stress distribution characteristics of mandibular implant-supported overdentures with four different bar attachment designs. Materials and Method: A photoelastic mandibular model with three implants (3.75 mm - 13 mm) placed at the interforaminal region was generated from a cast of an edentulous mandible. Four mandibular bar overdenture designs were fabricated: bar-clip, bar-galvano, bar-locator, and bar-ceka. Axial vertical loads (135 N) were applied to the central fossa of the right first molar area for each overdenture design. Stress concentrations were recorded photographically and analyzed visually. Results: The tested bar attachment designs revealed low and moderate stress levels. The lowest stress was observed with the bar-clip design, followed by bar-locator, bar-ceka, and bar-galvano designs. Conclusion: The loads were distributed to all of the implants. Studied designs experienced moderate stress levels around the loaded side implant. Bars with distally placed stud attachments and surface treatment with electroforming seems to increase stress levels around the implants. 
546 |a EN 
546 |a TR 
690 |a Dental stress analysis 
690 |a denture 
690 |a overlay 
690 |a denture precision attachment 
690 |a implant-supported dental prosthesis 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Acta Odontologica Turcica, Vol 34, Iss 1, Pp 8-13 (2017) 
787 0 |n http://dergipark.gov.tr/download/article-file/255034 
787 0 |n https://doaj.org/toc/2147-690X 
856 4 1 |u https://doaj.org/article/8c91844fb093485f94b4d6b7c3d6ad30  |z Connect to this object online.