A Three-dimensional Finite Element Analysis of Stress Distribution in Inclined Placed Implants
Introduction: Short implants are considered as a sole option in many patients due to anatomical limitations. It was aimed to assess the functional load stress at implants, surrounding bone and superstructures with different inclination angle. Methods: Seven finite element models with three implants...
Saved in:
Main Authors: | , |
---|---|
Format: | Book |
Published: |
Mashhad University of Medical Sciences,
2020-09-01T00:00:00Z.
|
Subjects: | |
Online Access: | Connect to this object online. |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
MARC
LEADER | 00000 am a22000003u 4500 | ||
---|---|---|---|
001 | doaj_8cc1e57f07504ea580aec94cca63476f | ||
042 | |a dc | ||
100 | 1 | 0 | |a Emel Yurekli |e author |
700 | 1 | 0 | |a Serhat Emre Ozkir |e author |
245 | 0 | 0 | |a A Three-dimensional Finite Element Analysis of Stress Distribution in Inclined Placed Implants |
260 | |b Mashhad University of Medical Sciences, |c 2020-09-01T00:00:00Z. | ||
500 | |a 2322-4150 | ||
500 | |a 2252-0317 | ||
500 | |a 10.22038/jdmt.2020.48218.1367 | ||
520 | |a Introduction: Short implants are considered as a sole option in many patients due to anatomical limitations. It was aimed to assess the functional load stress at implants, surrounding bone and superstructures with different inclination angle. Methods: Seven finite element models with three implants (4 mm × 8 mm) and a separate model with longer implants (4 mm× 10 mm) with an angulation of 37° were designed. The implants were first placed vertically and then angled in distal direction preserving their parallelism increasing 6 ° at each step. Chromium-Cobalt was used to prepare superstructures. Oblique force of 100 N was applied on superstructures. Result: Inclined implant replacement did not significantly increase stress and compressive forces on bone, and the stress on implant surrounding bone decreased as inclination angle increased. On the other hand, in the model with linger implant more homogenous stress distribution was observed and implant's von Mises values decreased. Conclusion: Inclination of implants could have no detrimental effects on bone. Furthermore, inclination of implants provides the opportunity of placing longer implants and also more favorable stress distribution around the implants and in bone. | ||
546 | |a EN | ||
690 | |a finite element analysis | ||
690 | |a dental implant | ||
690 | |a fixed partial denture, implant inclination, stress analysis | ||
690 | |a Dentistry | ||
690 | |a RK1-715 | ||
655 | 7 | |a article |2 local | |
786 | 0 | |n Journal of Dental Materials and Techniques, Vol 9, Iss 3, Pp 152-160 (2020) | |
787 | 0 | |n http://jdmt.mums.ac.ir/article_16424_7b9a35d1f916ec4e044c5b511961b649.pdf | |
787 | 0 | |n https://doaj.org/toc/2322-4150 | |
787 | 0 | |n https://doaj.org/toc/2252-0317 | |
856 | 4 | 1 | |u https://doaj.org/article/8cc1e57f07504ea580aec94cca63476f |z Connect to this object online. |