Evaluation of MBJ20® Transcutaneous Bilirubinometer in the Assessement of Severity of Neonatal Jaundice

The objective of this study was to evaluate the MBJ20® transcutaneous bilirubinonometer by Beijing M&B Electronic Instrument Co. Ltd. (Beijing, China) in the assessment of severity of neonatal jaundice. Two hundred and twenty-two paired samples from 88 newborns aged between 28 and 44 weeks of ge...

Full description

Saved in:
Bibliographic Details
Main Authors: Chinelo Madubuike (Author), Ebele F. Ugochukwu (Author), Obumneme Ezeanosike (Author), John Chukwuka (Author), Henry Okpara (Author)
Format: Book
Published: MDPI AG, 2016-10-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_8ce1aa02fc33410fb4cb1b86d5df97e5
042 |a dc 
100 1 0 |a Chinelo Madubuike  |e author 
700 1 0 |a Ebele F. Ugochukwu  |e author 
700 1 0 |a Obumneme Ezeanosike  |e author 
700 1 0 |a John Chukwuka  |e author 
700 1 0 |a Henry Okpara  |e author 
245 0 0 |a Evaluation of MBJ20® Transcutaneous Bilirubinometer in the Assessement of Severity of Neonatal Jaundice 
260 |b MDPI AG,   |c 2016-10-01T00:00:00Z. 
500 |a 2409-515X 
500 |a 10.3390/ijns2040008 
520 |a The objective of this study was to evaluate the MBJ20® transcutaneous bilirubinonometer by Beijing M&B Electronic Instrument Co. Ltd. (Beijing, China) in the assessment of severity of neonatal jaundice. Two hundred and twenty-two paired samples from 88 newborns aged between 28 and 44 weeks of gestation at Nnamdi Azikiwe University Teaching Hospital, Nnewi Anambra State, were analyzed. These infants had total serum bilirubin (TSB) levels measured on clinical indication, and transcutaneous bilirubin (TcB) levels were obtained at the forehead and sternum within 10 min of the TSB levels. There was a close correlation between TSB and TcBF and between TSB and TcBS for all the paired readings (n = 222, r = 0.904; n = 222, r = 0.917, respectively). MBJ20 values differed on average from the TSB values by 3.2 mg/dL for TcBF and 2.0 mg/dL for TcBs. We conclude that TcB measurements using the MBJ20 jaundice meter correlate very closely with TSB levels over the range of TSB encountered in this study and that estimation of TcB should be done at both the forehead and sternum. 
546 |a EN 
690 |a hyperbilirubinemia 
690 |a neonatal jaundice 
690 |a serum bilirubin 
690 |a MBJ20 transcutaneous bilirubinometer 
690 |a Pediatrics 
690 |a RJ1-570 
655 7 |a article  |2 local 
786 0 |n International Journal of Neonatal Screening, Vol 2, Iss 4, p 8 (2016) 
787 0 |n http://www.mdpi.com/2409-515X/2/4/8 
787 0 |n https://doaj.org/toc/2409-515X 
856 4 1 |u https://doaj.org/article/8ce1aa02fc33410fb4cb1b86d5df97e5  |z Connect to this object online.