Color Stability of Bulk-Fill Flowable Resin Composites After Artificial Aging

Background: This study aimed to evaluate the color stability of bulk-fill flowable resin composites with 2 difference shades at baseline and after artificial aging. Methods: Disk-shaped specimens (Ø10 × 4 mm) were fabricated from three bulk-fill flowable resin resin composites (Filtek Bulk-Fill Flow...

Full description

Saved in:
Bibliographic Details
Main Authors: Franciele Floriani (Author), Carlos A. Jurado (Author), Nikkita Madhu (Author), Mark A. Lackey (Author), Francisco X. Azpiazu-Flores (Author), Guilherme Carpena Lopes (Author)
Format: Book
Published: MDPI AG, 2024-10-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_8e5d2bbeb93c4d4d84742a96e2c255e5
042 |a dc 
100 1 0 |a Franciele Floriani  |e author 
700 1 0 |a Carlos A. Jurado  |e author 
700 1 0 |a Nikkita Madhu  |e author 
700 1 0 |a Mark A. Lackey  |e author 
700 1 0 |a Francisco X. Azpiazu-Flores  |e author 
700 1 0 |a Guilherme Carpena Lopes  |e author 
245 0 0 |a Color Stability of Bulk-Fill Flowable Resin Composites After Artificial Aging 
260 |b MDPI AG,   |c 2024-10-01T00:00:00Z. 
500 |a 10.3390/dj12110350 
500 |a 2304-6767 
520 |a Background: This study aimed to evaluate the color stability of bulk-fill flowable resin composites with 2 difference shades at baseline and after artificial aging. Methods: Disk-shaped specimens (Ø10 × 4 mm) were fabricated from three bulk-fill flowable resin resin composites (Filtek Bulk-Fill Flow, Venus Bulk-Fill Flow, and Estelite Bulk-Fill Flow). The specimens in each bulk-fill resin composite group were divided into two subgroups (n = 10 per subgroup) with two different shades, A1 (N = 30) and A3 (N = 30), and were polymerized with light curing (800 mW/cm<sup>2</sup>/Valo LED Unit, Ultradent) and polished. The color difference between bulk-fill resin composites was evaluated at baseline and after artificial aging using a spectrophotometer (CM-700d, Konica Minolta, Tokyo, Japan) under D65 illumination. Color coordinates were measured with CIEDE2000, and color differences (∆E<sub>00</sub>) and relative translucency parameter (RTP) values were calculated. Subsequently, the comparison of color changes (∆E<sub>00</sub>) before and after thermocycling was performed using the <i>t</i>-test for paired samples. Results: The bulk-fill flow resin composites evaluated in the present study were capable of mimicking important optical properties such as light transmission. All the resin composites provided acceptable color stability at baseline and after thermocycling when the color A1 was used. On the other hand, whenever the shade A3 was used, the Venus Bulk-Fill Flow demonstrated the best optical properties. There was no statistically significant difference when comparing baseline and after thermocycling in bulk-fill flowable resin composites (<i>p</i> > 0.05). After thermocycling, A1 bulk-fill flowable resin composites provided acceptable color stability, and all A3 bulk-fill flowable resin composites provided visible color change, except for the Venus Bulk-Fill Flow (∆E<sub>00</sub> = 2.35). Conclusions: Estelite Bulk-Fill Flow displayed the best color stability (∆E<sub>00</sub> = 2.22) between all the combinations evaluated. 
546 |a EN 
690 |a resin composite 
690 |a bulk-fill 
690 |a color 
690 |a flowable composite 
690 |a shade 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Dentistry Journal, Vol 12, Iss 11, p 350 (2024) 
787 0 |n https://www.mdpi.com/2304-6767/12/11/350 
787 0 |n https://doaj.org/toc/2304-6767 
856 4 1 |u https://doaj.org/article/8e5d2bbeb93c4d4d84742a96e2c255e5  |z Connect to this object online.