The effectiveness of hyperoxygenation in preventing oxygen desaturation in intubated infants treated with endotracheal suctioning

Endotracheal suctioning is an effective nursing intervention for intubated infants undergoing invasive mechanical ventilation. However, this intervention has the potential to cause side effects, such as hypoxemia, which typically requires hyperoxygenation. Despite the widespread use of hyperoxygenat...

Full description

Saved in:
Bibliographic Details
Main Authors: Sholihatul Amaliya (Author), Yeni Rustina (Author), Defi Efendi (Author)
Format: Book
Published: PAGEPress Publications, 2024-09-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_8ed18a94e20b4c8b9e20e9d1b220c49f
042 |a dc 
100 1 0 |a Sholihatul Amaliya  |e author 
700 1 0 |a Yeni Rustina  |e author 
700 1 0 |a Defi Efendi  |e author 
245 0 0 |a The effectiveness of hyperoxygenation in preventing oxygen desaturation in intubated infants treated with endotracheal suctioning 
260 |b PAGEPress Publications,   |c 2024-09-01T00:00:00Z. 
500 |a 10.4081/hls.2024.13045 
500 |a 2281-7824 
520 |a Endotracheal suctioning is an effective nursing intervention for intubated infants undergoing invasive mechanical ventilation. However, this intervention has the potential to cause side effects, such as hypoxemia, which typically requires hyperoxygenation. Despite the widespread use of hyperoxygenation in clinical practice, there are limited reports on its effectiveness in infants. This study aims to determine the effect of hyperoxygenation on oxygen saturation of intubated infants. The study procedures were carried out using a quasi-experimental method with a cross-over approach. In addition, the sample population comprised 22 intubated infants who were treated at the perinatology unit of Dr. Cipto Mangunkusumo Hospital in Jakarta from March to April 2018. The participants were then divided into 2 groups based on their condition, and oxygen saturation level was assessed. The intervention comprised endotracheal suctioning with and without hyperoxygenation, with a 3-hour washing period. Data collection was performed at different measurement intervals, namely before, during, and after suctioning, followed by statistical analysis. The paired-sample t-tests and Wilcoxon test showed that there was a significant difference in oxygen saturation at certain measurement intervals (p=0.006; p=0.010; p=0.001; p=0.001; p=0.001). In addition, Friedman test also showed the presence of a significant difference in the reduction of oxygen saturation between the control and intervention groups (p=0.001). In conclusion, hyperoxygenation had the potential to prevent the reduction of oxygen saturation during endotracheal suctioning in intubated infants. However, individual assessment of the need for suctioning and hyperoxygenation was necessary for a safe and effective procedure. 
546 |a EN 
690 |a Endotracheal suction 
690 |a hyperoxygenation 
690 |a intubated infant 
690 |a oxygen saturation 
690 |a Public aspects of medicine 
690 |a RA1-1270 
655 7 |a article  |2 local 
786 0 |n Healthcare in Low-resource Settings (2024) 
787 0 |n https://www.pagepressjournals.org/hls/article/view/13045 
787 0 |n https://doaj.org/toc/2281-7824 
856 4 1 |u https://doaj.org/article/8ed18a94e20b4c8b9e20e9d1b220c49f  |z Connect to this object online.