No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis

Background/Aims We compared outcomes between use of 15 vs. 20 mm lumen-apposing metal stents (LAMSs) in endoscopic ultrasound-guided gastroenterostomy (EUS-GE) for gastric outlet obstruction. Methods Databases were queried for studies that used LAMS for EUS-GE to relieve gastric outlet obstruction,...

Full description

Saved in:
Bibliographic Details
Main Authors: Shyam Vedantam (Author), Rahil Shah (Author), Sean Bhalla (Author), Shria Kumar (Author), Sunil Amin (Author)
Format: Book
Published: Korean Society of Gastrointestinal Endoscopy, 2023-05-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_8eedd054bdea4e90a34b974dbc9b99ae
042 |a dc 
100 1 0 |a Shyam Vedantam  |e author 
700 1 0 |a Rahil Shah  |e author 
700 1 0 |a Sean Bhalla  |e author 
700 1 0 |a Shria Kumar  |e author 
700 1 0 |a Sunil Amin  |e author 
245 0 0 |a No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis 
260 |b Korean Society of Gastrointestinal Endoscopy,   |c 2023-05-01T00:00:00Z. 
500 |a 2234-2400 
500 |a 2234-2443 
500 |a 10.5946/ce.2022.299 
520 |a Background/Aims We compared outcomes between use of 15 vs. 20 mm lumen-apposing metal stents (LAMSs) in endoscopic ultrasound-guided gastroenterostomy (EUS-GE) for gastric outlet obstruction. Methods Databases were queried for studies that used LAMS for EUS-GE to relieve gastric outlet obstruction, and a proportional meta-analysis was performed. Results Thirteen studies were included. The 15 mm and 20 mm LAMS had pooled technical success rates of 93.2% (95% confidence interval [CI], 90.5%-95.2%) and 92.1% (95% CI, 68.4%-98.4%), clinical success rates of 88.6% (95% CI, 85.4%-91.1%) and 89.6% (95% CI, 79.0%-95.1%), adverse event rates of 11.4% (95% CI, 8.1%-15.9%) and 14.7% (95% CI, 4.4%-39.1%), and reintervention rates of 10.3% (95% CI, 6.7%-15.4%) and 3.5% (95% CI, 1.6%-7.6%), respectively. Subgroup analysis revealed no significant differences in technical success, clinical success, or adverse event rates. An increased need for reintervention was noted in the 15 mm stent group (pooled odds ratio, 3.59; 95% CI, 1.40-9.18; p=0.008). Conclusions No differences were observed in the technical, clinical, or adverse event rates between 15 and 20 mm LAMS use in EUS-GE. An increased need for reintervention is possible when using a 15 mm stent compared to when using a 20 mm stent. 
546 |a EN 
690 |a endoscopic ultrasound 
690 |a gastric bypass 
690 |a gastric outlet obstruction 
690 |a gastrojejunostomy 
690 |a lumen apposing metal stent 
690 |a Internal medicine 
690 |a RC31-1245 
690 |a Diseases of the digestive system. Gastroenterology 
690 |a RC799-869 
655 7 |a article  |2 local 
786 0 |n Clinical Endoscopy, Vol 56, Iss 3, Pp 298-307 (2023) 
787 0 |n http://www.e-ce.org/upload/pdf/ce-2022-299.pdf 
787 0 |n https://doaj.org/toc/2234-2400 
787 0 |n https://doaj.org/toc/2234-2443 
856 4 1 |u https://doaj.org/article/8eedd054bdea4e90a34b974dbc9b99ae  |z Connect to this object online.