Wear of K3 and ProTaper files after simulated clinical use in curved canals

Objective: To assess wear, after simulated clinical use of K3 (SybronEndo, Orange, CA, EUA) and ProTaper files (Dentsply-Maillefer, Tulsa, Oklahoma, EUA) in 46 mesiovestibular roots of human maxillary first molars, recently extracted and with mean angulation of 40°.Methods: The teeth were divided as...

Full description

Saved in:
Bibliographic Details
Main Authors: Patrícia de Almeida Rodrigues Silva e Souza (Author), Mariana Diniz Bisi dos Santos (Author), Marília Fagury Videira Marceliano-Alves (Author)
Format: Book
Published: Faculdade São Leopoldo Mandic, 2009-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_9126245b81174459a8a04ff95faa817c
042 |a dc 
100 1 0 |a Patrícia de Almeida Rodrigues Silva e Souza  |e author 
700 1 0 |a Mariana Diniz Bisi dos Santos  |e author 
700 1 0 |a Marília Fagury Videira Marceliano-Alves  |e author 
245 0 0 |a Wear of K3 and ProTaper files after simulated clinical use in curved canals 
260 |b Faculdade São Leopoldo Mandic,   |c 2009-01-01T00:00:00Z. 
500 |a 0103-6971 
500 |a 1981-8637 
520 |a Objective: To assess wear, after simulated clinical use of K3 (SybronEndo, Orange, CA, EUA) and ProTaper files (Dentsply-Maillefer, Tulsa, Oklahoma, EUA) in 46 mesiovestibular roots of human maxillary first molars, recently extracted and with mean angulation of 40°.Methods: The teeth were divided as follows: a) K3 (SybronEndo, Orange, CA, EUA) (with radial bands) and b) ProTaper (Dentsply-Maillefer, Tulsa, Oklahoma, EUA) (without radial bands). The files were assessed by scanning electronic microscopy before first use to visualize fabrication defects, and after 7 and 13 cycles of debridement in the canals. Debridement with files K3 (SybronEndo, Orange, CA, EUA) and ProTaper (Dentsply-Maillefer, Tulsa, Oklahoma, EUA) was performed in accordance with the manufacturers' recommendations. The criteria for wear assessment were: defects (stretching, shortening/spiral inversion, presence of craters), oblique cracks and fracture. After assessment by SEM and before they were used, metal barbs on the crest of the spirals and oblique scratches due to the machining process were found in all the files.Results: In the K3 system (SybronEndo, Orange, CA, USA), after being used seven times, all the instruments showed cutting angle defects,and 25/08 and 25/10 had oblique cracks in the body of the active part leading to ductile fracture after being used for the eighth time. In the ProTaper system (Dentsply-Maillefer, Tulsa, Oklahoma, USA), after being used seven times, in addition to cutting angle defects, the files also presented cracks, and ruptile fracture occurred in F3 during use for the thirteenth time. At the end of preparation, craters were seen along the active part of the files.Conclusion: In the final analysis, it was seen that the system are equivalent with regard to the defects found, irrespective of the active part design,being proportional to the number of cycles of use, and these defects could act as points of greater fragility, favoring fracture. 
546 |a EN 
690 |a microscopy electron scanning 
690 |a endodontics 
690 |a instrumentation 
690 |a molar 
690 |a microscopia eletrônica de varredura 
690 |a endodontia 
690 |a instrumentação 
690 |a dente molar 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n RGO: Revista Gaúcha de Odontologia, Vol 57, Iss 1, Pp 13-18 (2009) 
787 0 |n http://www.revistargo.com.br/include/getdoc.php?id=3193&article=1098&mode=pdf 
787 0 |n https://doaj.org/toc/0103-6971 
787 0 |n https://doaj.org/toc/1981-8637 
856 4 1 |u https://doaj.org/article/9126245b81174459a8a04ff95faa817c  |z Connect to this object online.