Evaluation of torque loss in Co-Cr castable abutments after cyclic loading

Background and Aims: For the clinical success of implant-retained prostheses, fitness of matching components and stability of the applied torque to the implant-abutment assembly under dynamic occlusal loading is essential. The aim of this study was to evaluate the torque loss in Co-Cr castable abutm...

Full description

Saved in:
Bibliographic Details
Main Authors: Somayeh Zeighami (Author), Marzieh Alikhasi (Author), Maryam Memarian (Author), Moeen Hosseini Shirazi (Author)
Format: Book
Published: Tehran University of Medical Sciences, 2018-03-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_91f7253dbaa34d64b5b0866e8cdff61d
042 |a dc 
100 1 0 |a Somayeh Zeighami  |e author 
700 1 0 |a Marzieh Alikhasi  |e author 
700 1 0 |a Maryam Memarian  |e author 
700 1 0 |a Moeen Hosseini Shirazi  |e author 
245 0 0 |a Evaluation of torque loss in Co-Cr castable abutments after cyclic loading 
260 |b Tehran University of Medical Sciences,   |c 2018-03-01T00:00:00Z. 
500 |a 1024-641X 
500 |a 2008-2444 
520 |a Background and Aims: For the clinical success of implant-retained prostheses, fitness of matching components and stability of the applied torque to the implant-abutment assembly under dynamic occlusal loading is essential. The aim of this study was to evaluate the torque loss in Co-Cr castable abutments after cyclic loading. Materials and Methods: 10 castable abutments were cast in Co-Cr alloy with similar size and height. Each specimen was mounted vertically on a separated implant using a 30 Ncm tightening torque. The detorque values of the abutments were evaluated after 10 min. The same tightening torque was applied to the abutments on their corresponding implants and cyclic loading was applied for 500,000 cycles to the implant-abutment assembly. The torque values after cyclic loading were recorded for each specimen. T-test analysis was conducted on scores from the groups. Resultes: The results of this study showed that the percentage of torque loss in castable abutments was significantly increased after cyclic loading (P<0.001). Conclusion: Misfit between the castable implant components can cause torque loss before and after cyclic loading. However, it is more appropriate to relate the results of this study to the screw loosening of the above mentioned abutments than judging their clinical performance. 
546 |a FA 
690 |a Torque 
690 |a  Dental implants 
690 |a  Dental abutments 
690 |a Medicine 
690 |a R 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n Journal of Dental Medicine, Vol 30, Iss 4, Pp 192-199 (2018) 
787 0 |n http://jdm.tums.ac.ir/browse.php?a_code=A-10-661-2&slc_lang=en&sid=1 
787 0 |n https://doaj.org/toc/1024-641X 
787 0 |n https://doaj.org/toc/2008-2444 
856 4 1 |u https://doaj.org/article/91f7253dbaa34d64b5b0866e8cdff61d  |z Connect to this object online.