A Comparative Evaluation of the Stability of Four Processing Solutions (Champion, Cronex, Teifsaz, Novin) in Processing of Intraoral Films After Time Intervals

Introduction. In order to obtain good radiographs having optimum processing solution is important. Generally after a period of time the solutions will be oxidized and loose their efficacy. The goal of present research is comparison of the quality stability of four processing solutions available in m...

Full description

Saved in:
Bibliographic Details
Main Authors: E - Hekmatian (Author), M Mahdizadeh (Author), GhR Rostami (Author)
Format: Book
Published: Isfahan University of Medical Sciences, 2005-01-01T00:00:00Z.
Subjects:
Online Access:Connect to this object online.
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000 am a22000003u 4500
001 doaj_9265dba5e00b4b51b606ad7101985b98
042 |a dc 
100 1 0 |a E - Hekmatian  |e author 
700 1 0 |a M Mahdizadeh  |e author 
700 1 0 |a GhR Rostami  |e author 
245 0 0 |a A Comparative Evaluation of the Stability of Four Processing Solutions (Champion, Cronex, Teifsaz, Novin) in Processing of Intraoral Films After Time Intervals 
260 |b Isfahan University of Medical Sciences,   |c 2005-01-01T00:00:00Z. 
500 |a 1735-255X 
500 |a 2008-6989 
520 |a Introduction. In order to obtain good radiographs having optimum processing solution is important. Generally after a period of time the solutions will be oxidized and loose their efficacy. The goal of present research is comparison of the quality stability of four processing solutions available in market "Champion, Teifsaz, Cronex and Novin".Methods and Materials. One hundred and twenty eight intraoral radiographic films of one type with specific speed were exposed under identical exposure factors. A metal step wedge was used for the image. Each 4 days two periapical films were exposed and processed this was continued for two months. Finally optical density of radiographs processed in each solution were measured and compared according to the day of investigation.Results. All of the four solutions created acceptable density on the radiographs on the first day but there was a decrease in optical density after a period of time. Generally the Champion solution made the best density and after that were Cronex, Teifsaz and Novin. There was a decrease in the quality of Teifsaz, Cronex, Champion and Novin in order.Discussion. As the composition and percentage of these four solutions are different, the stability of them are also different. Champion was found to have the best quality among three other processing solutions.Key words. Processing solution, Quality, Stability, Champion, Teifsaz, Cronex, Novin. 
546 |a FA 
690 |a Key words. Processing solution 
690 |a Quality 
690 |a Stability 
690 |a Champion 
690 |a Teifsaz 
690 |a Cronex 
690 |a Novin. 
690 |a Dentistry 
690 |a RK1-715 
655 7 |a article  |2 local 
786 0 |n مجله دانشکده دندانپزشکی اصفهان, Vol 1, Iss 2, Pp 15-18 (2005) 
787 0 |n http://jids.mui.ac.ir/index.php/jids/article/view/4 
787 0 |n https://doaj.org/toc/1735-255X 
787 0 |n https://doaj.org/toc/2008-6989 
856 4 1 |u https://doaj.org/article/9265dba5e00b4b51b606ad7101985b98  |z Connect to this object online.